Casals REINTAIR S 300 AC Manual De Uso Y Mantenimiento página 47

Purificador de aire sin instalación
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

REG REINTAIR REGULATOR CONFIGURABLE PARAMETERS
To access the parameters mode, in normal operating mode press MODE continuously (approx. 2s) until the user menu appears on the screen
(date setting, time programming, identifier, parameters, reset of the G4 filter operating time, reset of the operating time filter H14 and regula-
tor reset). With the UP and DOWN keys select PAr and press MODE, accessing the parameter mode at that moment.
Note: During parameter mode, the regulator does not communicate on the serial communication channel.
In parameter mode the functions of the buttons are as follows:
- ON/OFF: Exits parameter mode.
- MODE: Accepts the value of the displayed parameter and goes to the next parameter.
- GO UP: Increases the value of the parameter.
- GO DOWN: Decrease the value of the parameter.
Parameter list
P1. RUNNING HOURS G4 FILTER FOR DIRTY FILTER INDICATION (range: 0ff, 00001h to 09000h; default: 04000h
OFF Function disabled
00001...09000 Function enabled
P2. HOURS OF OPERATION FILTER H14 FOR DIRTY FILTER INDICATION (range: 0ff, 00001h to 09000h; default: 07305h)
OFF Function disabled
00001...09000 Function enabled
P3. MINIMUM VOLTAGE FAN SPEED (range: 0.0V to 5.0V; default: 2.0V)
P4. MAXIMUM VOLTAGE FAN SPEED (range: 6.0V to 10.0V; default: 9.5V)
P5. UV-C LAMP CONTROL (range: 0 to 4; default: 0)
0: UV-C lamp disabled.
1: UV-C lamp enabled (operation according to schedule, Parameters 7 and 8, Record 16).
Activation only if purifier on (fan on, Record 51 ≠ 0). Fan speed = Fan speed setpoint (Record 3).
2: UV-C lamp enabled (operation according to schedule, Parameters 7 and 8, Record 16).
Activation only if purifier on (fan on, Record 51 ≠ 0). Fan speed = Parameter 6 (Record15, low byte).
3: UV-C lamp enabled (operation according to schedule, Parameters 7 and 8, Record 16).
Independent activation of the purifier on / off. Fan speed = Fan speed setpoint (Record 3).
4: UV-C lamp enabled (operation according to schedule, Parameters 7 and 8, Record 16).
Independent activation of the purifier on / off. Fan speed = Parameter 6 (Record 15, low byte).
P6. FAN SPEED WITH UV-C LAMP ACTIVATED (range: 20% to 100%; default: 30%)
P7. UV-C LAMP CONTROL START TIME (range: 00:00 to 23:00; default: 19:00)
P8. UV-C LAMP CONTROL FINAL TIME (range: 00:00 to 23:00; default: 06:00)
P9. COMMUNICATIONS ADDRESS (range: 1 to 240; default: 1)