Regular maintenance will extend the life of this generator and improve its performance. The warranty does not
cover items that result from operator negligence, misuse, or abuse. To receive full value from the warranty,
operator must use the generator as instructed in this manual, including proper storage.
Before inspecting or servicing this machine, make sure the engine is off and no parts are
WARNING!
moving. Disconnect the spark plug wire and move it away from the spark plug.
If you are unsure of how to perform a maintenance task, have the unit serviced by an
CAUTION!
authorized PULSAR dealer.
CAUTION!
Only use specified PULSAR replacement parts.
Pre-Operation Steps
Before starting the engine, perform the following pre-operation steps:
•
Check the engine oil and the fuel tank level.
•
Make sure the air filter is clean.
•
Remove any debris that has collected on the generator and around the muffler and controls. Use a vacuum cleaner to
pick up loose debris. If dirt is caked on, use a soft bristle brush.
•
Inspect the work area for hazards.
After Each Use
Turn the FUEL VALVE Knob to "OFF"
•
Switch OFF the engine
•
Switch Off the battery
•
Wait for the generator to become cool to the touch
•
Store unit in a clean and dry area.
•
Maintenance Schedule
After First 5 Hours
After 8 Hours or Daily Clean Debris from Generator and Air Filter area
Annually (25 hr Use)
Annually (100 hr Use) Service Spark Plug (Replace with NGK BP6ES, Champion N9YC or equivalent)
MAINTENANCE
Change Oil
Check Engine Oil Level
Check and Clean Air Cleaner
Change Engine Oil after the first 25 hours, again at 50 hours; then every 100
hours thereafter.
Inspect Muffler and Spark Arrester
Inspect Fuel Valve and Fuel Lines for leaks or damage
Inspect Muffler and Spark Arrester
Check and Clean Air Cleaner Assembly, Replace Air Filter
Clean Cooling System Cylinder Head Fins and Flywheel Fan
18