GENERAL WARNING
•
This hood has been developed and produced in accordance with
DS/EN 60335-1.
•
This hood is intended for home use only. Using for other purposes
will make the warranty invalid.
•
All installations must be carried out by a qualified technician in
accordance with the instructions set out by Thermex Scandinavia
A/S (Thermex) and the Laws in force.
•
Thermex disclaims any liability for damage resulting from im-
proper installation, assembly, operation or incorrect settings.
BEFORE INSTALLATION/OPERATION
•
check the hood for transport damage, defects and missing parts
immediately upon receipt.
•
Transport damage should be reported immediately to the trans-
port company and Thermex upon receipt.
•
Any defects and/or missing parts should be reported to Thermex
within 8 days of receipt and prior to installation/operation.
INSTALLATION
•
The hood is designed to operate at 230 volts ± 10% ~ 50 Hz ±10%
in accordance with EN 50160
•
connect the hood with the attached plug. NOTE: If the plug has
an Earth terminal, the hood MUST be earthed.
•
For models with an external motor it is important NOT to use
common zero when installing the hood and motor, as this will af-
fect operation.
•
when using an external motor from another supplier, the motor
MUST be compatible with the selected hood. Failure to comply
with this will invalidate the warranty.
•
The hood must not be connected to the mains before installation
is complete.
•
The air must not be discharged from the hood into a pipe used for
extraction from devices using gas or other combustible materials.
Such devices must have a separate vent.
•
The national law and building regulations etc. for air emissions
must be observed.
•
Always use the original exhaust measurements. Reduction of the
exhaust size will reduce performance and increase sound levels.
•
The exhaust from the hood to the outside should be as short as
possible in order to maximise the efficiency of the hood.
•
The number of bends on the exhaust should be minimal in order
to maximise the efficiency of the hood.
•
Thermex recommends that vent hoses insulated against noise
and condensation for all bushings in unheated rooms are always
used.
•
Thermex recommends using a silencer when flexible hoses are
used in order to minimise sound levels.
•
when using flexible hoses, always ensure that they have been
fully extended in order to minimise air resistance and thereby
maximise suction performance.
•
Different materials require different rawlplugs and screws.
Rawlplugs and screws suitable for the material onto which the
hood will be mounted on must be used.
•
If the instructions for the installation of screws and fittings are
not followed, it may result in electrical shock.
•
The minimum distance to gas hobs from the burner's edge to the
underside of the hood MUST be a minimum of 65 cm in accord-
ance with EN 60335-2-31.
•
For cupboard-integrated, suspended and wall-mounted hoods,
Thermex recommends that the distance between the hob and
cooker hood is between 50 cm and 70 cm in order to ensure max-
imum suction.
•
Always check the minimum distance between the hob and the
cooker hood, as indicated in the instructions for the hob. The
instructions for the hob MUST be observed if a greater distance
than that recommended by Thermex is indicated in this manual.
•
Thermex recommends that the distance between the hob and the
hood should not exceed 3 metres for ceiling-integrated models.
THERMEX METz MIcRO