Be sure to use appropriate
protective gear and unplug unit.
WARNING:
Make sure area is well
ventilated and free of flammable vapors.
WARNING:
SELECTING THE PROPER SPRAY
NOZZLE - (FIGURES B AND B1)
The sprayer includes two standard nozzles
that are colored coded for ease of
identification.
Fan (wide) nozzle (green - figure B) - This
nozzle has a spring attached to the back
which allows for adjustments for spraying
both vertically and horizontally. It also has
tabs on the side which match the spray
pattern when set for spraying side to side
and top to bottom. The spray pattern covers a wide area. This is the spray nozzle that is identified as number 1 in the
diagram on top of the sprayer.
Cone nozzle (blue - figure B1) - The cone nozzle spray pattern is more concentrated. Use this nozzle for items that
are too small for the fan nozzle. This is the spray nozzle that is identified as number 2 in the diagram on top of the
sprayer.
ATTACHING THE SPRAY NOZZLES - (FIGURES C AND C1)
To attach the green fan spray nozzle:
• Make sure cord is unplugged.
• Thread the nozzle onto the spindle until
you feel a little resistance (about 10 full
turns).
• Push in on the spring loaded nozzle and
turn until it is fully seated (figure C).
• Once the nozzle is fully seated, the spring
on the back of the nozzle will make it pop
out slightly when it is released (figure C1).
• Make sure fan spray nozzle is completely
threaded on by hand only. If it is not fully
seated in can leak or damage the nozzle.
To remove the green fan spray nozzle:
• Press in on the nozzle and turn
counterclockwise.
To attach the blue cone spray nozzle:
• Thread the nozzle onto the spindle until it is fully seated.
• Make sure cone spray nozzle is completely threaded on by hand only. If it is not fully seated in can leak or damage
the nozzle.
ADJUSTING THE FAN SPRAY NOZZLE - (FIGURES D AND D1)
To adjust the fan spray nozzle:
• Make sure cord is unplugged and that the
fan spray nozzle is fully hand-tightened.
• The fan spray nozzle has two tabs which
align to indicate vertical and horizontal
positions.
• If you will be spraying (side to side) adjust
the nozzle to align with the vertical mark as
shown in figure D.
• If you will be spraying (up and down) adjust
the nozzle to align with the horizontal mark
as shown in figure D1.
Do not compress or push
spring when adjusting fan pattern. The
CAUTION:
nozzle should rotate and not loosen.
B
SET-UP
C
D
7
B1
C1
C1
D1