Safety
2. Safety
This section describes the safety warnings and the Personal Protective Equipment used in the unit.
2.1. Safety conditions
General warnings
DANGER
Opening the enclosure does not imply there is no voltage inside.
Only qualified personnel may open it, following the instructions in this manual.
CAUTION
The operations described in the manual may be performed only by qualified personnel.
The status of qualified personnel referred to in this manual will be, as a minimum, that which meets all the
standards, regulations and laws regarding safety applicable to the tasks of installing and operating this unit.
The responsibility for designating qualified personnel will always fall to the company to which the personnel
belong. It is necessary to decide which workers are suitable or not for carrying out specific work to preserve their
safety at the same time as complying with occupational safety legislation.
These companies are responsible for providing appropriate training in electrical equipment to their personnel
and for familiarizing them with the contents of this manual.
All applicable safety-related legislation for electrical work must be complied with. Danger of electric shock.
Compliance with the safety instructions set out in this manual or in the suggested legislation does not imply
exemption from other specific standards for the installation, place, country or other circumstances that affect
the inverter.
You must consider the set of conditions listed throughout this document as minimum requirements. It is always
preferable to shut off the main power supply. There may be faults in the installation that cause the unwanted
return of voltage. Danger of electric shock.
According to basic safety standards, the complete unit must be suitable to protect exposed workers against the
risk of direct and indirect contact. In any case the electrical parts of the work equipment must comply with the
provisions of the corresponding specific regulations.
According to basic safety standards, the electrical installation shall not entail a fire or explosion risk. Workers
must be duly protected against the risk of accidents caused by direct or indirect contact. The electrical
installation and protection devices must take into account the voltage, the external conditions and the
competence of persons who have access to parts of the installation.
2.2. Personal Protective Equipment (PPE)
When working on the unit, use the following recommended safety equipment as a minimum.
Name
Safety footwear
Helmet
Helmet with face shield
Working clothes
Dielectric gloves
Tools and / or equipment used in live work must have at least Category III-1000 Volts insulation.
Should the country's regulations demand another kind of personal protection, the recommended equipment should
be appropriately supplemented.
ABA2017IQM01_B - Installation and Operation Manual
In compliance with standard UNE-EN-ISO 20345:2012
In compliance with standard EN 397:1995
In compliance with Standard UNE-EN 166:2002, wherever there are directly
accessible live parts.
Close-fitting, non-flammable, 100% cotton
In compliance with standard EN 60903:2005
Explanation