Technical data
NOTE
Technical data
Additional specifications and notices for using the device can be found
in the operating instructions.
Operating voltage
Average current consumption
Integrated LED illumination
Transmitter/receiver
Sensor field widthOGS 600-280/...
Distance between sensor and floor 10 ... 70mm,
Measurement time
Linearity error
Measurement value resolution
Guide trace width
Guide trace color
Branches
Interface type
Switching inputs/outputs
Degree of protection
VDE protection class
Housing
Optics cover
Weight
Ambient temp. (operation/storage) -15°C ... +50°C / -30°C ... +60°C
Rel. air humidity
Standards applied
Conformity
Certifications
1) Protective Extra Low Voltage (PELV) - protective extra-low voltage.
20
2) Only with screwed-on M12 connectors or mounted caps
OGS 600-140/...
OGS 600-.../CN...
OGS 600-.../D3...
OGS 600-.../D2...
OGS 600-280/...
OGS 600-140/...
18 ... 30VDC (PELV
Approx. 180 mA at 24 V DC
(no load at switching output)
Red, wavelength 634nm, risk group 0 (exempt
group) in acc. with EN 62471:2008
49 transmitter and 49 receiver elements
300mm
150mm
Nominal:
30mm
Optimal:
20 ... 40mm
10ms
Typ. 5mm (at a sensor-floor distance of 30mm)
Typ. 1mm (at a sensor-floor distance of 30mm)
Ideally 40mm, at least 10mm
Light trace on dark floor,
dark trace on light floor,
see operating instructions for information on
contrast
Switch filter, see operating instructions
CANopen and RS232
RS485
RS422
1 switching output (all OGS 600s),
1 configurable switching input/output
(only OGS 600s with RS485 or RS422)
2)
IP 65
III
Diecast aluminum
Polycarbonate
Approx. 405g
Approx. 245g
Max. 90% (non-condensing)
EN 60947-5-2:2007+A1:2012
CE
c UL US
1)
, Class 2)