Descargar Imprimir esta página

Alpha FA-G2 Instrucciones página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Introduction:
FA-G2 power supply has been exclusively designed to be used
on Alpha Communications (Alpha) G2+ video door entry system.
Alpha will not be responsible of the possible damages caused for
an improper use or when used for other purposes than the
specified.
Features:
- Universal AC input/full range.
- Multi protection: Short circuit and overload.
- Integrated with Bus splitter (monitor/ door panel).
- Additional Bus splitter (monitor/ door panel) is not needed.
- DIN 46277 rail mounting.
2. Terminal description:
N
L
L
N
12240100
INPUT ~100-240V
FA-G2+
0.8A 50-60Hz
OUTPUT
BUS 30V 2V 1. A
±
5
BUS BUS
GOLMAR S.A. C/ Silici, 13 08940 - SPAIN
N: AC input.
L: AC input.
LED: Power indicator, always on when plug in power.
BUS(M): Monitor connection bus terminal.
BUS(PL): Door panel connection bus terminal.
3. Installation:
1: Mount the din rail to the wall with wallplugs and screws that
are suplied with power supply.
2: Place the power supply simply pressing it.
DIN rail latch release.
Alpha Communications reserves the right to make any modifications without prior notice.
FA-G2 POWER SUPPLY INSTRUCTIONS
LED
V02
MADE IN CHINA
PL
BUS(M) BUS(PL)
Din rail.
Din rail.
4. Wiring:
Open the AC protection cover:
1. Remove the protection cover
fixing screw
2. Push up the protection cover.
3. Next pull it out.
When the installation and wiring works are finished, place the
protection cover before replacing the electrical current.
*
AC Input
100~240Vac
N
L
Connect to monitor
Note:
The installation and handling of this equipment must be
performed by authorised personnel and without the power
connected.
5. Specification:
Input Voltage:
Input Frequency:
Rated Output Voltage:
Rated Output Current:
Working Temperature:
Dimensions:
6. Warning:
-This device has been exclusively designed to be used on Alpha
G2+ video door entry system. Alpha will not be responsible of the
possible damages caused for an improper use or when used for
other purposes than the specified.
-The installation and handling of this equipment must be performed
by authorized personnel and without the power connected.
-Install the power supply in a dry and protected place with enough
ventilation, without risk of drip or water projections.
-Install the power supply according to your country rules.
-Do not use excessive force when tightening the power supply
connector screws.
-The device must be protected by using a thermo-magnetic circuit
*
breaker.
-The power supply must be unplugged from mains during
installation or maintenance progresses.
-To avoid an electrical shock, neither remove the protection cover
nor handle the connected wire in the terminals without first
disconnecting the power supply.
-Do not block ventilation holes of the unit so that air can circulate
freely.
-To avoid damage, the power supply has to be firmly fixed.
-Once the power supply has been installed, place the supplied
protection cover on the mains input connector ('N' & 'L').
-Before switching the system on, check that there is no short circuit
on the installation.
-In case of system failure, unplug it from mains by using the thermo-
magnetic circuit breaker and contact an authorized Alpha after
sales service.
-This document must be kept together with the device.
1
2
BUS(M)
BUS(PL)
Connect to door panel
100~240Vac
50~60 Hz
30 Vdc
±
2V
1,
5A
-10ºC ~ 40ºC
140*90*60mm
AWD283 Rev. Oct 2020
3

Publicidad

loading