drenching rain showerhead
Spray Change
Button
Shower
Arm Nut
Collar
Flexible Arm
Spray Change
Button
Bracket
Adapter
5' hose
Instruction Manual
Flow Control
Waterpik
®
showerheads are equipped with an OptiFLOW
limits maximum water flow to 2.5 gallons per minute at 80 psi
as mandated by U.S. federal law.
In areas with extremely low water pressure, causing
the shower water flow to be unsatisfactory, the
flow regulator may be removed to improve
the water flow in the showerhead.
To remove, unscrew
filter screen by turning
counterclockwise.
Remove regulator
with needle-nose
Filter Screen
pliers and replace
Washer
filter screen.
Flow Regulator
Filter
Screen
Flexible Installation
Your new showerhead will fit a standard 1/2" shower arm. Do not
attach this product to a plastic shower arm since it may not provide
adequate support.
Tools are not required. Do not use pipe tape or any other sealants when
installing the showerhead. These materials are not necessary and may cause
the nut to loosen prematurely. Hand tightening is sufficient to secure the
shower thread. Make sure the washer is in the end of the nut.
1. Remove old showerhead. Clean pipe threads thoroughly.
2. Attach the flexible shower arm collar to the
showerhead, being careful to align
the threads.
3. While installing, support the showerhead and hold onto the
Models:
nut rather than the cover. Turn only the nut to tighten.
Do not twist the flexible shower arm covering
CF-200
during installation. (This could damage the
CF-201
covering and/or cause the product to
CF-201C
malfunction.) Take care in aligning
CF-203C
the nut to the shower pipe so you
CF-209C
do not cross threads.
CF-261
4. Tighten the shower nut onto the pipe
CF-263C
securely by hand. Do not over
tighten or use pliers.
5. Slowly turn on cold water and check for leaks. If leaks occur, retighten
all connections.
6. Do not use excessive force in positioning the showerhead and/or arm.
7. If the showerhead is not maintaining its position, re-tighten the
showerhead collar and shower arm nut.
Hand-Held Installation
®
regulator that
1. Remove old showerhead. Clean pipe threads thoroughly.
2. Slightly loosen swivel collar on bracket.
3. Hand tighten pivot ball to pipe.
4. Hand tighten adaptor to showerhead.
5. Hand tighten hose to adapter and bracket.
6. Place showerhead in bracket.
Nut
Flow Regulator
(black O-ring faces out)
Operation
To change settings, from
either the full-body spray
or the concentrated power
spray, push the spray
change button at the base
of the showerhead so it
extends to the opposite
side of its current position.
Spray Change Button
Spray Change Button
Operation
Clean the filter screen at least once a year, or when you notice a drop in
water pressure. To remove, unscrew the nut from the pipe. Remove the
screen by turning it counter-clockwise (pliers may be used) and rinse.
If you remove the flow regulator, be sure you reinstall it with the black O-ring
facing out.
• Cleaning is required when mineral deposits appear on the spray holes to
maintain proper working conditions.
• Clean the flexible nozzles by rubbing with a finger or soft bristled toothbrush.
• Do not clean or rinse any part with harsh chemicals, heavy-duty cleaners or
abrasives. This may damage parts or finish and may void the warranty.
Limited Lifetime Warranty
Water Pik, Inc. warrants to the original purchaser of this product that
it is free from defects in material and workmanship for as long as the
original purchaser owns this product. Water Pik, Inc. will at our election,
repair or replace any part of the product which in our opinion is defec-
tive, provided that the product has not been abused, misused, altered
or damaged after purchase. (This includes damage due to use of tools
or harsh chemicals.) In the event an item has been discontinued we will
replace with what we deem to be the closest product. Water Pik, Inc.
is not responsible for labor charges, installation, or other consequential
cost. The responsibility of Water Pik, Inc. shall not exceed the original
purchase price of the product. This warranty gives you specific legal
rights. You may also have other rights that vary where you reside. Save
your receipt as proof of purchase is required for warranty action.
U.S. Patent Numbers: 5,865,378; 5,997,047 (Lic);
6,164,570 (Lic); 6,626,210; 6,629,651;6,641,057; D440,641;
D452,897; D485,887
Have any questions or need assistance?
If in the U.S., call our toll-free
If outside the U.S., write us at:
Customer Assistance Line,
Water Pik, Inc.
1-800-525-2774
1730 East Prospect Road
Fort Collins, CO 80553-0001
USA
www.waterpik.com
®
®
®
Waterpik
, Waterpik
(stylized), Cascadia
, and OptiFLOW
registered trademarks of Water Pik, Inc.
© 2006 Water Pik, Inc.
Water Pik, Inc.
1730 East Prospect Road, Fort Collins, CO 80553-0001 USA
www.waterpik.com
FN 20007764-F AB
®
are