2 . General safety precautions
!
Disconnect the power supply before attempting any work on the unit .
• During installation, the electric power cable to be connected must not be live.
Therefore, switch off the power first and use a voltage tester to make sure the
wiring is off-circuit.
• Installing the light involves work on the mains voltage supply. This work must there-
fore be carried out professionally in accordance with national wiring regulations and
electrical operating conditions.
• Only use genuine replacement parts.
• Repairs may only be made by specialist workshops.
• Not suitable for use with halogen lamps.
3 . Spot ONE Sensor/Spot DUO Sensor
Spot ONE Sensor Connect/Spot DUO Sensor Connect
Proper use
– LED light with sensor for indoor and outdoor wall mounting
Spot ONE Sensor/Spot DUO Sensor
– The sensor-switched LED light contains an infrared motion detector.
Spot ONE Sensor Connect/Spot DUO Sensor Connect
– The sensor-switched LED light contains an infrared motion detector and can only
be adjusted via Bluetooth.
16
Spot ONE package contents (Fig . 3 .1)
– Luminaire
– Three screws
– Three wall plugs
– Three spacers
Spot DUO package contents (Fig . 3 .2)
– Luminaire
– Four screws
– Four wall plugs
– Four spacers
Spot ONE product dimensions (Fig . 3 .3)
Spot DUO product dimensions (Fig . 3 .4)
Product parts (Fig . 3 .5)
A
Wall mount
B
Connecting terminal
C
Locking screw
D
Light base
E
Light enclosure
F
Twilight setting (Spot ONE/DUO Sensor only)
G
Time setting (Spot ONE/DUO Sensor only)
Spot ONE/DUO Sensor detection zone (Fig . 3 .6-3 .8)
4 . Electrical connection
Wiring diagram (Fig . 4 .1)
The supply lead is a three-core cable:
L = phase conductor (usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors using a voltage tester; then disconnect
from the power supply again. Connect phase (L), neutral (N) and protective-earth
conductor (PE) to the terminal.
Important:
Incorrectly wired connections will produce a short circuit later on in the product or
fuse box. In this case, you must identify the individual conductors once again and re-
connect them. A mains power switch for turning the unit ON and OFF may of course
be installed in the mains supply lead.