1
A.
3
2
B.
3
3
Note: The Sensori
®
rough (R66000-WS) must be installed before
installing the trim.
A.
Turn off water supplies from main or
inlet stops (1). Remove
plasterguard (2), bonnet nut (3) and test cap
(4) from the body.
B.
Verify presence of either o-ring (on some
models) or friction bushing (4) located on
splined valve stem.
Locate flats (1) on cartridge (2) and inside
of sleeve (3). Align flats and insert cartridge
into sleeve being careful not to push on
copper element at end of cartridge.
1
4
R66000-WS
4
1
1
Thermostatic Valve
C.
5
D.
2
1
C.
Locate "V" (1) on cartridge sleeve and "V"
notch (2) on valve body (3). Align the "Vs"
and press sleeve and cartridge assembly
(4) into valve body (3) and note the "UP"
position (5).
D.
Slide bonnet nut (1) over the cartridge and
thread onto the body.
Hand tighten securely.
3
1
1
4