Descargar Imprimir esta página

Miscellaneous; Residual-Current Device (Rcd) - Danfoss TLX 6k Serie Manual Del Usuario

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59

6. Miscellaneous

6.1. CLX Portal
6.1.1. How to Register the TLX Pro+ Inverter on the CLX Portal
For instructions on how to register the TLX Pro+ inverter on the CLX Portal, go to:
www.danfoss.com/solar → [Products → CLX Portal → How to register].
6.2. UTE Requirements in France
For installation in France, apply warning label to front of inverter.
Illustration 6.1: Position of Warning Label

6.3. Residual-current Device (RCD)

The design of TLX leads to a DC leakage current exceeding 6 mA during single fault conditions.
Consult local guidelines to choose the correct RCD type, dependent on:
-
grid type
-
whether the RCD is used to ensure automatic disconnection
-
whether the RCD is used to provide additional safety
Note:
For low-voltage grids in Denmark, an RCD Type B is required according to the local guide-
lines.
L00410591-04_4z
6. Miscellaneous
6
17

Publicidad

loading

Este manual también es adecuado para:

Tlx+ 6kTlx pro+6k