56 00
With the gate completely open, recloses 6 seconds after photocell interruption
00
OFF (photocell interruption does nothing)
01
the interruption of FT1 causes the closure
02
the interruption of FT2 causes the closure
60 01
Brake at the end of the manoeuvre
00
OFF (brake disabled at the end of the manoeuvre)
01
ON (brake at the end of the manoeuvre)
61 01
Brake on photocell intervention
00
OFF (brake disabled whenever a photocell intervenes)
01
ON (brakes whenever a photocell intervenes)
62 01
Brake on STOP command
00
OFF (brake disabled whenever the STOP command intervenes)
01
ON (brakes whenever the STOP command intervenes)
63 01
Brake on reversal (AP-CH o CH-AP)
00
OFF (brake disabled before reversing the motion)
01
ON (brakes before reversing the motion)
64 05
Brake duration
01
20
TENTHS OF A SECOND
-
Change carefully, choosing a low value to prevent the leaf from restarting, rather than braking.
65 08
Force applied by the brake
01
08
1 minimum force ... 08 maximum force
-
71 01
Position of the motor with respect to the gap
00
motor positioned on the LEFT with respect to the gap looking from the inside
01
motor positioned on the RIGHT with respect to the gap looking from the inside
NOTE: parameter
Changes the direction of rotation of the motor for opening and closing, also changes the interpretation
of the limit switches so as not to reverse the cables.
72 01
Limit switch enabling
00
no limit switch connected to the control unit
01
opening and closing limit switch connected to control unit
02
only the opening limit switch connected to the control unit
NOTE: parameter