distance, respect it.
The unit must not be mounted above cookers fitted with top radiant plate.
For proper operation it is recommended to install the product at a distance
of 200 – 210 cm from the floor.
Respect all the air discharge regulations.
The air must not be discharged in a pipe used to discharge exhaust fumes
produced by gas-fed equipments or fuel-fed equipments (this does not
apply to filtering hoods).
The room must be adequately ventilated when the hoods is used together
with other gas or fuel equipments.
For an easy access, it is advisable to move possible furniture under the
installation area.
The hood is equipped with all the necessary fastenings for its installation,
which are suitable for most surfaces. Verify that the installation surface
is strong.
Installation must be carried out by qualified installers according to
present regulations.
The hood can be installed in two different ways:
•Fixed with the motor directly on the ceiling (possible only when the
distance between the ceiling and the false ceiling is between 247 and
318mm). Follow the visual instructions Fig. 1-2-3-4-5-6.
•Fixed with the motor directly on the false ceiling. Follow the visual
instructions Fig. 7-8.
The motor can also be positioned away from the hood at a distance not
longer than 7m. In this case the hood can only be used in the exhausting
version. If the motor is installed on the wall it is prohibited to have the air
outlet on the side. Fig. 9

ELECTRICAL CONNECTION

This equipment must be connected to a grounding plant.
Two types of electrical connection can be used:
1.Using a standard plug to be connected to the power cable and inserted
in a mains socket which must be accessible (so that the plug can be
disconnected when servicing is carried out). Make sure that the plug is
www.velgehome.com
accessible also after the complete installation of the equipment.
2.By means of a fixed mains connection, fitting a bipolar switch, which
ensures the disconnection, with an opening distance of the contacts
allowing a complete disconnection on the conditions of the overvoltage
III category, according to installation regulations. The ground connection
(yellow-green wire) must not be interrupted.
Refer to the plate inside the hood for the mains voltage and frequency
ratings.
If the power cable is damaged, it must be replaced by the manufacturer or
by its service agent or a qualified person in order to avoid any risk.
USE
This cooker hood can be employed as exhausting or filtering.
Exhausting (external evacuation). Kitchen smokes are driven outside
through a flue joined to the exhaust pipe flue connector. This pipe must
not under
any circumstances be connected to cooker, boiler or burner exhaust pipes,
etc.
Filtering (inside recycling). In this case it is essential to install the the
activated carbon filters on the motor. Waste gases and vapours when
cooking are filtered through active carbon filters, depurated and re-
circulated into the kitchen through a tube connected to the ducting fitting
(spigot) on the cookerhood.
OPERATION
The hood is supplied with a multispeed motor.
The hood should be run at low speed under normal conditions and at
higher speeds only when there is a heavy build-up of fumes or odours.
Ideally, the hood should be switched on as soon as cooking is started and
then kept on until all odours have been eliminated.