INSTALLATION
Line Voltage Landscape Illuminator:
1.
Fixture Mounting:
Mount 1/2" NPS threaded knuckle onto suitable
enclosure (Cover, Ground spike, Enclosure). Aim and
Secure fixture stem to mounting option with
provided lock nut if applicable.
2.
Wiring:
Make electrical connections using waterproof wire
nuts (recommended) Connect lead wires to
secondary supply wires and ground. Seal with
supplied dielectric sealing compound.
3.
Relamp Options:
MR16: To install MR-16 lamp into fixture, unscrew
front bezel push lamp pins into small holes in socket,
replace bezel. If bezel becomes difficult to screw
into body, then loosen small set screws on the outer
shroud and screw bezel onto body. Do not over
tighten small set screws. (Figure 1.)
LED Module: If already lamped, make sure fixture
has cooled down before attempting to remove old
lamp. Once fixture is sufficiently cooled, remove
the 4-40 screws and pull out module. Do not twist.
Remove new Lumiere LED module from box and
remove nuts from the 4-40 screws. The nuts are
used for shipping purposes. Visually align the
mounting holes with the threaded holes in the fixture
base and the Bi-pin connectors with corresponding
receptacles in socket base. Gently insert the new
Lumiere LED module into the base ensuring pins
are aligned with the socket and firmly press LED
module until positively seated. Insert and tighten the
4-40 screws that lock LED heat sink to the fixture
base. (Figure 2.)
Figure 1.
Lumiere LED Module
High Mode (10W) Switch to Left
Low Mode (6W) Switch to Right
Figure 2.
Installation Instructions – Sanibel 301
ADL141324
www.cooperlighting.com
Installation Instructions – Sanibel 301
Front Bezel
MR-16: 50 Watt Max.
Or
LED: 15W Max.
Swivel
1/2 NPT
Locknut
Lead Wires
Ground
#4-40 Screws
HI
LO
Transformer
Housing