Troubleshooting; Corrective Action - Lincoln 1162 Manual Del Usario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

AUTOMATIC AIR GREASE GUN
MODEL 1162
Conditions
The gun doesn't operate
The gun doesn't operate
automaticaly.
The gun cycles but doesn't Loss of prime.
pump grease.
The gun continues to lose Air may be trapped in
prime.
If the gun still doesn't
operate.
Page Number - 8

TROUBLESHOOTING

Possible cause
No inlet air pressure.
The piston (7) is stuck.
Air pressure is too low.
Broken return spring (12). Replace if nessesary.
Air pressure is too low.
The piston (7) is stuck.
The container is out of
grease.
Prime is not achieved
after 10-15 seconds of
operation.
several locations
in container after bulk
fillling.
The follower lips (11) are Refer the paragraph on the container tube.
positioned wrong
The ball check valve (3) Disassemble check valve, remove ball,
is not functioning.

Corrective action

Connect air supply.
Dissasemble the gun, inspect for damage.
Replace if nessesary.
Check air pressure supply. The pressure
is to be higher 40 psi.
Check air pressure supply. The pressure
is to be higher 40 psi.
Disconnect air supply hose and hold on
until the spring is retracted the piston back
and cycle the gun. If the gun doesn't oper-
ate
dissasemble the gun, inspect for damage.
Replace the piston if nessesary.
Repeat priming operation.
Check that container has grease.
Disconnect the extension hose or rigid
extension and cycle the gun until grease
flows from the outlet.
Empty container, refill and repeat priming.
clean and inspect ball seat area.
Contact an authorized service center.
Form 420110

Publicidad

Tabla de contenido
loading

Tabla de contenido