If the temperature excedes 43°C, it is necessary to use personal protective equipment,
such as gloves to thermally insulate your hands from the unit.
The use of solvents and/or detergents that contain halogenated hydrocarbons (trichloroethane,
methyl chloride, etc.), may cause chemical reactions in the unit as well as in its zinc-coated compo-
nents (trichloroethane mixed with small amounts of water produces hydrochloric acid). For this
reason, these components may rust and in extreme cases the chemical reaction caused may be
explosive. We recommend you to use products that do not contain the aforementioned compo-
nents. Do not use acids, soda (alkalis or pickling substances, etc.) for cleaning under any circum-
stances.
In general, precautions must be taken whenever the gun is handled, in order to prevent any damage
to this.
Connectors must be securely tightened and in good condition. Safety standards must be understood
and applied.
Any non-compliance with the indications set out in this manual may lead to incidents affecting the
physical integrity of the user or other personnel or animals.
Respect and comply with indications relating to the conservation of the environment.
Always keep the safety sheets for the products to apply and the cleaning liquids to hand in case you
need to consult them.

12. Troubleshooting

ANOMALIES
Skipping
Spattering
Bubbling in cup
Not Spraying
Double Line
CAUSES
Air pressure too high
Paint too thick
Airbrush is dirty
Nozzle not seated on body
Nozzle damaged or cracked
Dried paint on tip of needle
Dried paint on tip of needle
Airbrush is dirty
Paint too thick
Air pressure too low
Loose nozzle nut
Nozzle damaged or cracked
Clogged nozzle
Loose nozzle nut
Loose needle packing screw
Improper air pressure
Paint too thick
Nozzle damaged or cracked
Airbrush is dirty
Bent needle
Dirt on tip of nozzle or in air cap
Nozzle damaged or cracked
Dried paint on tip of needle
ENGLISH
REMEDY
Reduce pressure
Dilute
See Cleaning section
Tighten the nozzle and
nozzle nut (by hand or
lightly with wrench)
Replace the Nozzle
Clean the Needle
Clean the Needle
See Cleaning section
Dilute
Increase air pressure
Tighten the nozzle and
nozzle nut (by hand or
lightly with wrench)
Replace the Nozzle
See Cleaning section
Tighten the nozzle nut (by
hand or lightly with wrench)
Tighten
Adjust pressure
Dilute
Replace the Nozzle
See Cleaning section
Replace or straighten
needle
Flush with solvent or
remove and soak parts
Replace the Nozzle
Clean the Needle

Publicidad