9�4�3
Connector CN3 - 7 pin female
Connector CN3 is used to connect optional Control Panel Item no 452 via connection cable Item no 2065.
Pin
A
CAN1 High
B
CAN1 Low
C
Earth (*)
D
CAN1 +Vdc
E
CAN1 0Vdc(**)
F
+ V_Panel
G
0V_Panel
(*) The communication cable shield is connected to pin C.
(**) Pin E is earthed with a 10nF capacitor in parallel with a 10 MOhm resistor.
For details, refer to the Item no 452 instruction manual code 3301082.
9�4�4
Connector CN4 - 10 pin female
Connector CN4 is used to interface with the Emergency+Varc optional kit Item 449. This kit allows management
of an external emergency signal, according to
Pin
Type
Description
1
DIn
+24Vdc_EM1
2
DIn
0Vdc_EM1
3
DIn
+24Vdc_EM2
4
DIn
0Vdc_EM2
5
-
Not used
6
DOut
Eme_State-1
7
DOut
Eme_State-2
8
AOut
V_Arc - Not used
9
Not used
10
AOut
V_Arc + Not used
For more details, refer to the instruction manual of the Kit Item no 449 - code 3301060.
The use of non-original accessories may compromise the correct operation of the power source and even the
integrity of the system, rendering any warranty and liability cover that CEBORA S.p.A. may provide for the welding
power source null and void.