6.�.�
Current measurement (CH1 and CH2)
Sensor
Shunt (CH1 only)
30 A clamp (CH1 only)
100 A clamp
600 A clamp
1000 A clamp (CH1 only)
6.�.�
Continuity tester (CH1)
Property
Measurement current
Open circuit voltage
Continuity
6.�.6
Diode measurement (CH1)
Property
Measurement current
Open circuit voltage
Maximum diode voltage
Robert Bosch GmbH
Measurement range
±600 mA
±30 A
±100 A
±600 A
±1000 A
Value�Range
2 mA
≤ 5 V
< 10 (with acoustic response)
Value�Range
2 mA
≤ 5 V
2 V
�echnical data | ��S ��� � ��S ��� � ��S ��� | 29
��S ��� � ��S ��� � ��S ��� | 29
6.�
Oscilloscope specifications
Measuring channel 1 (CH1)
Measuring channel 2 (CH2)
Input resistance > 900 kOhm.
Property
Measurement range
Coupling
Signal source
X-deflection
Trigger mode
Trigger source
Pretrigger time
Frequency range
Memory depth
per channel
6.�
Power pack
Property
Input voltage
Input frequency
Output voltage
Operating temperature
6.6
Bluetooth Class 1
Wireless connection
��S ���, ��S ��� to PC�Laptop
Workshop environment
in the open space
If the vehicle door or window is
open and the engine is still run-
ning in the vehicle interior
| 29
zero potential
potential based
Value�Range
0 — 200 V
DC, AC,
DC(+) (only positive range is shown),
DC(-) (only negative range is shown).
U, 30 A (CH1 only), 100 A,
600 A, 1000 A (CH1 only),
Diagnosis pins 1 to 15
(not pins 4, 5)
50 µs — 1 s
Manual, Auto-Time, Auto-Level
CH1, CH2
0 — 80 %
> 1 MHz (typical 5 MHz)
50 signal curves with 512 coordinates
Value�Range
90 — 264 VAC
47 — 63 Hz
15 V
0 °C — 40 °C
Minimum range
30 meters
10 meters
|
1 689 979 987
2008-07-02