Descargar Imprimir esta página

Mounting Cut - Out - HEATSTRIP CROSSRAY+ TCS4FL Instrucciones De Armado

Ocultar thumbs Ver también para CROSSRAY+ TCS4FL:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24

MOUNTING CUT - OUT

Refer to the this table for show the minimum Cut out
size when designing the island unit.
Model
Width
TCS4FL
928mm
250mm
Depth
Height
Width
the minimum distance of the unit is 900mm from combus-
tibles. the minimum height of the island unit is 800mm start-
ing from the ground up.
Height
Depth
260mm
447mm
Non-combustible
Construction
ENGLISH
PRECAUTIONS
NOTE: When installing a barbecue equipped for liquid propane in an
island, the
gas cylinder
isolated from the barbecue. It must be cross-ventilated in accordance
with the current standard. The
directly under the barbecue. NOTE: Upper & lower ground-level vents (20
sq. in.(130 cm 2 ) minimum each) MUST BE PROVIDED for combustion
air on both sides of built-in construction.
Vented on
Both Sides
of Island
Non-combustible
Contruction
Vented Access Door
10
must be in a separate enclosure that is completely
gas cylinder
MUST NEVER be installed
Clamp down
flexline

Publicidad

loading

Productos relacionados para HEATSTRIP CROSSRAY+ TCS4FL

Este manual también es adecuado para:

Crossray+ tcs4pl