Translation of the original instructions
• This product should be disposed of at an appropriate recy-
• Recyclable product that falls within waste sorting recom-
CONNECTING THE BATTERY TESTER
1- Make sure that the area is well ventilated before performing a test.
2- Tester for 6 V and 12 V batteries.
3- Before running a test on the battery, ensure that the ignition and the consumers are switched off. Close all doors
and the boot.
4- Make sure that the battery connections are clean. If necessary, clean them with a wire brush.
Any presence of oxidation between the tester terminals and the battery connectors or between the battery
connectors and the battery terminals reduces the effectiveness of the tester.
5- Connect the negative (black) terminal to the negative terminal of the battery. Connect the positive terminal (red) to
the positive terminal of the battery.
BATTERY TEST - Reaction of the tester after 10 seconds of charging
CHARGING TEST
Batterie OK (green line)
Low or defective battery (yellow line)
Low battery or battery to be replaced (red line)
START TEST
1. Make sure all vehicle consumers are switched off (lights, air conditioning, radio etc.).
2. Start the engine, one of these two results is displayed:
Examples
The indicator displays a voltage below 9.6 V
The indicator shows a voltage higher than 9.6 V
6
cling facility. Do not dispose of in domestic waste.
mendations
TBP 100
BATTERY STATUS
The battery is operational.
The battery is either defective or discharged. Recharge the
battery to maximum and test again. If the result is the same,
replace the battery
A problem at the cell level is observed (short circuit.....). Replace
the battery. Or the battery is nearing the end of its life. Replace-
ment required.
The starting voltage is not correct. The battery must be replaced.
The starting voltage is normal.
Analysis