Grounding JetNet 4508 / 4508f
There is one grounding screw on the bottom side of
JetNet 4508/4508f. Connect the frame grounding of
JetNet 4508/4508f to the grounding surface to ensure
safety and prevent noise to interfere communication.
Wiring the Power Inputs
1. Insert the positive and negative wires into the V+ and V- contact on the terminal block
connector.
2. Tighten the wire-clamp screws to prevent the power wires from being loosened.
Notes: The recommended working voltage is DC 24V (Input range: DC10~ 60 V),
maximum power consumption is 10 Watts.
Wiring the Relay Output (DO)
The relay output contacts are in the bottom side as shown on Figure-3. The relay output (DO)
the User's Manual for the Relay Output information.
Figure-3
Note: The relay contact only
supports 1A current, DC 24V.
It is not recommended to apply
voltage and current higher than