FIGURE F
TRIM MOULDING
SCREW #12A x 2" LONG
(USE 3)
SILL PLATE GUIDE CHANNEL
INSIDE WALL SURFACE
Slide the cabinet into the hole far enough to allow the guide-channel of the sill plate to con tact the inside wall surface (See
STEP 6
Figure F).
Drill three (3)
STEP 7
Figure F).
NOTE: ALTERNATE FASTENERS WHICH MAY BE USED FOR SECURING THE SILL PLATE IN THE WALL AND THE SUP-
PORT BRACKETS TO THE OUTSIDE WALL (NOT FURNISHED BUT AVAILABLE AT LOCAL HARDWARE STORE).
MOLLY OR TOGGLE BOLT
Drill two (2)
STEP 8
(Item # 4, page 2). Provided that Step 5 (hole construction) provides a sturdy mount with solid vertical studs, no support brack-
ets are required. The installation must support the weight of the unit plus an additional weight of 400 pounds on the rear of the
cabinet.
If support brackets are available, they can certainly be used for through-the-wall installations as shown in Figure F.
If the reliability of the wall is in question, a window installation kit which includes support brackets can be ordered (see
Accessories).
If desired, trim around the cabinet on the room side with a suitable frame moulding furnished by the installer (see Figure F).
STEP 9
STEP 10
Complete the installation by following steps 13 through 18 of SASH WINDOW INSTALLATION IN STRUC TIONS, Pages 7
and 8.
STEP 11
Refer to the "OPERATING GUIDE" for instructions.
TYPICAL INSTALLATION
5
⁄
" dia. pilot holes through holes in sill-plate into framing and install three (3) #12A x 2" long screws (See
32
5
⁄
" dia. pilot holes each side at the locations shown (see Figure F, page 13) and install four (4) #12A x 2" screws
32
920-036-05 (10-04)
CAULK ALL SIDES AIR TIGHT
NOTE: SUPPORT BRACKETS MAY BE OMIT TED
FROM THROUGH-THE-WALL IN STAL LA TIONS IF THE
CABINET IS SECURED AS FOL LOWS. DRILL 2 HOLES
IN EACH SIDE AND IN STALL 4 FAS TEN ERS (2 EACH
SIDE). USE #12 x 2" SCREWS, TOGGLE BOLTS OR
EX PAN SION ANCHOR BOLTS AS SHOWN IN STEP 7.
SUPPORT BRACK ETS AVAILABLE AS OP TION AL AC CES SO RY.
SCREW #12 x 2" LONG, USE ONE EACH
5
BRACKET. DRILL
⁄
32
EXPANSION ANCHOR BOLT
⅜" SLOPE DOWN
DIA. PILOT HOLES.
13