WIRING
CAUTION: Be sure fan and switches are properly grounded and all
wiring complies with local electrical code requirements.
1. Run 120V, power wiring to the thermostat outlet box and secure
with a box connector. Use 14 gauge wire with ground. See
wiring diagram
2. It is suggested that an on/off switch be installed in a convenient
location in the living quarters of the house so the fan can be
turned off when not needed.
ADJUSTING THE THERMOSTAT
The fan thermostat is preset at 110°F. The fan will automatically
start when the ambient temperature reaches that level and stop
when the temperature drops10 degrees below the set temperature.
Starting temperature can be adjusted from 60°F to 120°F.
OPTIONAL ACCESSORY
Model AHS-200 Automatic Heat Sensor will automatically shut down
the Attic Fan if, for any reason, the temperature in the attic reaches
200°F.
MAINTENANCE
CAUTION: Before cleaning or servicing unit, make sure power
is disconnected at service panel. (See important safety
instructions on page 1.)
At the beginning of each ventilating season, check fan for any
debris that may be blocking fan blades, screen, or motor ventilation
openings.
WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period
of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES
FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident,
improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.
NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS
WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.
Date of Installation
Model No. and Product Description
Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599.
Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9.
(Sold separately)
One Year Limited Warranty
Builder or Installer
IF YOU NEED ASSISTANCE OR SERVICE:
For the location of your nearest NuTone Independent Authorized Service Center:
Residents of the contiguous United States Dial Free 1-800-543-8687
Please be prepared to provide:
Product model number • Date and Proof of purchase • The nature of the difficulty
To extend motor life, lubricate motor at the beginning
of each ventilating season. Oil ports are located on the
front and back of the motor. Use 5 or 6 drops of 20W
non-detergent motor oil in each port.
SUGGESTED LOCATION OF VENTILATION
NAILING PATTERN
Product specifications subject to change without notice.
4820 Red Bank Road, Cincinnati, Ohio 45227
Printed in U.S.A., Rev. 3/02, Part No. 25633
Rev. 03/2001