SPECIFICATIONS
Output Circuit Type
Output Power in watts
FTC: 20 Hz to 20 kHz, 0.1% THD 8 ohms
both channels driven
EIA: 1 kHz, 0.1% THD
both channels driven
Bridged Mode
at 0.1% THD
Input Sensitivity for rated power into 8 ohms
Input Impedance
Voltage Gain
Dynamic Headroom at 4 ohms
Distortion, SMPTE
Frequency response at 1 watt
Damping Factor
Noise (unweighted)
Controls
Connectors
LED Indicators
Cooling
Amplifier Protection
Load Protection
Power Requirements
Circuit Breakers
AC Connection
Current Consumption at 120V (in amperes) at typical/full/maximum output power (idle current= 1 amp)
8 ohms
4 ohms
2 ohms
Current Consumption Notes:Typical- 1/8 power, pink noise, represents typical program with occasional clipping. Full- 1/3 power, pink noise, represents severe pro-
gram with heavy clipping. Maximum- continuous sine wave at 1% clipping.
AC Inlet:
Supplied Cord Set
Weight
Dimensions
complementary bipolar output with multi-step high efficiency circuit
RMX 4050HD
800
4 ohms
1300
2 ohms
1600
8 ohms
850
4 ohms
1400
2 ohms, 1% THD
2000
8 ohms, 20 Hz to 20 kHz
2600
8 ohms, 1 kHz
2800
4 ohms, 1 kHz, 1% THD
4000
1.25 Vrms
20 k ohm balanced, 10 k ohm unbalanced
64x (36 dB) for 8 ohm load
2 dB
<0.02%
20 Hz to 20 kHz, 8 ohms, LF Filter bypassed: +0, -1 dB
5 Hz to 50 kHz, 8 ohms, LF Filter bypassed: +0, -3 dB
>250, 8 ohm load
100 dB below rated output from 20 Hz to 20 kHz, 8 ohm load
Front Panel- AC power switch, CH1 Gain control, CH2 Gain control
Rear Panel- 10-pole DIP switch featuring LF Filter on/off, LF Filter 30/50 Hz, Clip Limiter on/off controls
for each channel and switches for selecting Stereo, Parallel, or Bridge Mode. Push-button circuit
breaker for each channel.
Inputs: XLR female, TRS (1/4-inch), and barrier-strip screw terminals provided for each channel
Outputs: binding posts and Speakon outputs (CH1 Speakon wired for bi-amp connection)
Power "on", green; Protect, red; Signal -35 dB, yellow (1 each channel); Clip, red (1 each channel)
continuously variable speed fan, rear to front airflow
short circuit, open circuit, thermal, ultrasonic, and RF protection;
stable into reactive/mismatched loads
turn-on and turn-off muting, DC fault output crowbar
100, 120, or 240 Volts AC (±10%) 50-60 Hertz
RMX 4050HD: two (one for each channel): 100 and 120 V models: 15 amp / 230 V models: 8 amp
RMX 5050: two (one for each channel): 100 and 120 V models: 20 amp / 230 V models: 10 amp
detachable 3-conductor grounded, Class 1 type
RMX 4050HD
typical= 6.4, full= 12.5, maximum= 25.5
typical= 10.0, full= 20.1, maximum= 42.2
typical= 14.5, full= 30.6, maximum= 65.7
IEC 6032 C13
120V: 8ft (2.5m), NEMA 5-15 plug
230V: 8ft(2.5m), CEE7/7 plug
68 lb. (30.8 kg) net, 77 lb. (34.9 kg) shipping
19.0" wide x 5.2" (3RU) high x 15.9" deep (482x132x404mm)
Specifications are subject to change without notice.
RMX 5050
1050
1600
2000
1100
1800
2500
3200
3600
5000
1.42 Vrms
RMX 5050
typical= 8.7, full= 17.0, maximum= 34.4
typical= 13.9, full= 26.9, maximum= 56.4
typical= 18.9, full= 38.0, maximum= 84.7
IEC 6023 C19
120V: 8ft(2.5m), NEMA 5-20 plug
230V: 8ft(2.5m), CEE7/7 plug
75 lb. (33.1 kg) net, 87 lb. (37.2 kg) shipping
EN
9