Operation
1. Push the gas cartridge up into the port on the cooler (fig. a, page 9).
!
WARNING!
Never check for leaks with an open flame or near sources of ignition.
2. Check all connections with leak spray.
There are no leaks at the connections if no bubbles form.
Before moving the cooler:
➤ Take out the gas cartridge.
6.7
Using the cooler in gas mode
Proceed as follows (fig. b, page 10):
1. Turn the cooling level controller (fig. 4 2, page 4 and fig. 5 2, page 5) to the
maximum position.
2. Press and hold the cooling level controller.
3. After 10 seconds, press the ignition button (fig. 4 3, page 4 and fig. 5 3,
page 5) several times quickly in succession until the flame is lit.
✔ After ignition, you can see the flame in the sight glass (fig. 2 5, page 3 and
fig. 3 5, page 4).
4. Hold down the cooling level controller for another 20 seconds.
To switch off the cooler:
➤ Close off the gas valve on the cooler and on the gas cylinder.
6.8
Defrosting the cooler
A
NOTICE!
Never use mechanical tools to remove ice or to loosen objects stuck to
the device.
I
NOTE
Over time, frost builds up on the cooling fins inside the cooler. If this
layer of frost is about 3 mm thick, you should defrost the cooler.
26
ACX3
EN