Maintenance (continued)

CHANGING THE OIL

When changing the pump oil, be sure to do the
following:
Turn the unit off and unplug the power cord from
the receptacle.
Allow the compressor time to cool if it has been
in operation.
Open the drain valve (3) to bleed all the air from
the tank.
Close the drain valve (3).
Remove the oil fill cap/breather (1) on the pump.
Remove the sight glass (2) with a box-end
wrench or socket. Drain the oil into a suitable
container and dispose of properly. The
compressor may need to be tipped slightly
towards the drain hole to allow all of the oil to
drain.
Reattach the sight glass (2). Torque the sight
glass 10-12 inch lbs. when re-assembling. Be
sure the gasket is between the sight glass and
the pump crankcase.
Refill the compressor pump with an air
compressor oil, such as SAE-30 non-detergent,
Semi Synthetic oil, at slow intervals until the oil
reaches the center of the red circle in the sight
glass (2). Use a SAE-10 during extreme winter
conditions.

Care and Cleaning

Drain the air tank of moisture after operation.
When not in use, store the compressor in a cool, dry place.
Disconnect the air hose and hang open ends down to allow any moisture to drain.
Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them
loosely around the compressor handle.