Safety Instructions:
Non-compliance with the safety instructions can result in danger both to persons and to the
environment and the equipment. Non-compliance with the safety instructions can lead to the
loss of any claims for damages. The operatoof the equipment must ensure that the contents
of the Operating Instructions, particularly the Safety Instructions are known to the operating
personal.
-
The pressure in the air feed line must not exceed 8 bar.
Before any repair or maintenance work, the air connection should be loosened.
-
-
The use of accessory components e.g. hoses and connection fittings, which are not supplied by
MATO, can in some cases give rise to the risk of accidents. No liability can be accepted for
accidents or damage caused by components from other sources.
-
Protect hoses from damage and the effects of heat.
-
Replace damaged hoses immediately with genuine spare parts.
-
Modification or alteration to the equipment is only permissible after discussion with the
manufacturer.
-
The operational safety of the equipment is only guaranteed if used in accordance with the
directions.
-
Maintenance, inspection and repairs must only be carried out by qualified specialist personnel,
who have acquainted themselves with the subject by studying the operating instructions.
Technical Data:
Size of unit
Pressure ratio
Max. delivery pressure at
8 bar air supply pressure
Delivery per double stroke
Grease NLGI Class 000
Grease NLGI Class 2
Air pressure min./max.
Sound level:
(perceived sound level)
Thread
Air connection
Grease outlet
Suction tube diameter
Suction tube length
Weight
(pump & motor unit)
pneuMATO fill
10-25 kg
50 kg
3500 ccm / min
1750 ccm / min
ca. 67 dB(A)
525 mm
790 mm
5,5 kg
5,6 kg
200 kg
1000 l
1:3
24 bar
20 ccm
3 – 8 bar
Rp ¼"
R ½"
40 mm
940 mm
1490 mm
5,8 kg
5,9 kg
9