Approx. 3 s after the last press of
the decade keys or by pressing
the Reset key the new preset
value will be accepted and the
counter will switch back to
operating mode.

7.9.2 Setting with Teach-In Function

Program the MPI input to tEAch
In programming mode, select the
preset to be changed using the
Prog/Mode key
Briefly activate the MPI (NPN or PNP input logic)
The current count value will be adopted as
the new preset value
The preset value can subsequently be
further modified via the decade keypad.
7.10

Set Function

Both the pulse counter and the timer can be set to
a default value by means of the Set function.
Programme the MPI input to SEt
Set menu item SEtPt to the
desired value
Briefly activate the MPI (NPN or PNP input logic)
For add. output operations the pulse
counter or timer will be set to the SEtPt
default value
For sub. output operations the pulse
counter or timer will be set to the
difference between the value of Preset 2
and the value of SEtPt .
8

Error message

Err 1
Set value is outside the permitted range
www.kuebler.com
9

Connections

9.1

Signal and Control Inputs

N° Designation
1
AC: 24 VDC/80 mA
DC: U
connected
B
through
2
GND (0 VDC)
3
INP A
4
INP B
5
RESET
6
LOCK
7
GATE
8
MPI
9.2

Supply voltage and Outputs

N° Designation
9
Collector 1
10 Emitter 1
11 Emitter 2
12 Not connected
13 Collector 2
14 AC: 100...240 VAC
± 10% N~
DC: 10...30 VDC
15 AC: 100...240 VAC
± 10% L~
DC: GND (0 VDC)
16 Common-Emitter
17 Collector 6
18 Collector 5
19 Collector 4
20 Collector 3
Function
Sensor supply
voltage
Common connection
Signal and Control
inputs
Signal input A
Signal input B
Reset input
Keypad lock
Gate input
User input
Function
Output 1
Output 2
Supply voltage
Supply voltage
Output 3 to 6
Output 6
Output 5
Output 4
Output 3
Page 17