Note
If further modules are to be connected to the controller, the sub-address
(SA) has to be entered fi rst.
To register the module in the controller, use the same number that has
been selected as sub-address!
Example: If SA = 2, register the Regtronic EM as module 2 in the controller.
Adjustments on the second module:
Î Assign the sub-address (SA = 2).
ACTUAL state
Adjustments on the controller:
Î Select module 2.
ACTUAL state
Î Activate a further heating circuit (heating circuit 3).
Î Carry out the adjustments as described above.
ACTUAL state
TARGET state
TARGET state
TARGET state
!
!
!
4
Operation
4.1
Buttons
The device is operated via the 3 buttons next to the display.
Button : scrolling backwards through the menu or increasing adjustment values
Button : scrolling forwards through the menu or decreasing adjustment values
Button : changing to the adjustment mode or confi rming
If an adjustment value is shown on the display, SEt is displayed. Briefl y press button
in order to access the adjustment mode.
0 Auto I
4.2
Selecting channels and adjusting values
Î Select the requested channel using buttons and
Î Briefl y press button , SEt fl ashes (adjustment mode)
Î Adjust the value by pressing buttons and
Î Briefl y press button
SEt permanently appears, the adjusted value is stored.
27