Descargar Imprimir esta página

Grandstream GDS3710 Guía De Instalación Rápida página 7

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13
GDS3710 WIRING TABLE
Jack
Pin
Signal
1
TX+ (Orange/White)
2
TX- (Orange)
3
RX+ (Green/White)
4
RX- (Green)
PoE_SP2 (Blue + Blue/
5
J2
White)
(Basic)
PoE_SP1 (Brown + Brown/
3.81mm
6
White)
7
RS485_B
8
RS485_A
9
GND
10
12V
1
GND
2
ALARM1_IN+
3
ALARM1_IN-
4
ALARM2_IN+
J3
5
ALARM2_IN-
(Avanced)
6
NO1
3.81mm
7
COM1
8
NO2
9
COM2
10
NC2
1
GND (Black)
2
WG_D1_OUT (Orange)
3
WG_D0_OUT (Brown)
4
LED (Blue)
J4
(Special)
5
WG_D1_IN (White)
2.0mm
6
WG_D0_IN (Green)
7
BEEP (Yellow)
8
5V (Red)
For more details regarding GDS3710 wiring, please
refer to User Manual.
~
Function
Ethernet,
PoE 802.3af Class3.
12.95W
RS485
Power Supply
Alarm GND
ALARM IN
Alarm Out
Electric Lock
Wiegand Power GND
WIegand Output Signal
Wiegand Output LED
Signal
Wiegand Input Signal
Wiegand Output BEEP
Signal
Wiegand Power Output
~
9
Electric Lock
Type
Power On Power Off
Fail Safe
Lock
Open
Fail
Open
Lock
Secure
NOTE:
Please select the correct wiring based on different electric
*
strike/lock and the normal status of door.
*
Electric Magnetic Lock will work at Fail Safe mode ONLY.
Note:
1) Power PoE_SP1, PoE_SP2 with DC, the voltage range is 48V~57V,
no polarity.
2) Power with PoE the cable wiring:
• PoE_SP1, brown and brown/white binding
• PoE_SP2, blue and blue/white binding
3) DC Power could be correctly sourced from qualified PoE Injector.
This product is covered by one or more of the U.S. patents (and any foreign patent counterparts thereto)
identified at www.cmspatents.com.
GDS3710 Connection
Door
Normal
NC2
NO2
COM2
Status
Lock
Open
Lock
Open
~
~
10

Publicidad

loading