22. Shrink the wraparound sleeve
Preheat evenly along both sides of the rail/channel area until this
area begins to shrink. To achieve uniform heating, move the flame
back and forth from one side of the channel to the other as shown
in illustration "A" while moving flame along the entire length of the
channel as shown in illustration "B" until the sleeve starts to shrink.
This technique will assure a properly preheated rail and channel area.
Begin shrinking at the center of the sleeve and work toward each
end.
Apply heat until the sleeve is fully shrunk and the heat-sensitive green
paint is completely converted to black. Continue heating the rail/
channel area for another 5 seconds per foot. A white line should be
visible in the channel gaps indicating sufficient heating.
Note: Green heat-sensitive paint will turn black as sleeve shrinks
in place.
This completes the splice.
Note: Allow to cool before moving or placing in service.
The Information contained in these installation instructions is for use only by installers trained to make electrical power installations and is intended to describe the correct method
of installation for this product. However, Tyco Electronics Corporation has no control over the field conditions which influence product installation. It is the user's responsibility to
determine the suitability of the installation method in the user's field conditions. Tyco Electronics' only obligations are those in Tyco Electronics' standard Conditions of Sale for this
product and in no case will Tyco Electronics be liable for any other incidental, indirect or consequential damages arising from the use or misuse of the products.
TE (logo) and Tyco Electronics are trademarks. Copyright 2006, 2007, 2010 Tyco Electronics Corporation. All Rights Reserved.
PII 53106
Revision AL
A
White indicator
Adhesive Flow (Both Ends)
8
B
Torch
127
PCN 690615-000
Effective Date: June 17, 2010