Mounting Instructions - Hansgrohe AXOR Urquiola 42500000 Instrucciones De Empleo Y Montaje

Ocultar thumbs Ver también para AXOR Urquiola 42500000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 10
User instructions
EN
Permissible use
The radiator may only be used to heat interiors and to dry/heat
up temperature-resistant textiles. Any other use is impermissible.
Misuse
The radiator may not be used as climbing aid.
Safety instructions
Risk of getting burnt at hot surfaces!
The surfaces of the radiator and of the connections
can have temperatures of up to 90 °C.
Be careful when touching the radiator.
Protect your children.
Danger of scalding through hot water
spurting out!
The radiator is equipped with an automatic bleed valve.
Do not carry out any manipulation at the bleed valve
in order to ensure the leak-tightness of the radiator.
There are magnets that can delete magnetic data me-
dia, such as bank cards, at the heating fields/empty
elements.
Mounting and repairs
Have the mounting and repairs only carried out by specialist
fitters so that your warranty claims do not lapse.
Small scratches at the cover can be eliminated by using a
paint spot repair stick.
Cleaning
Observe the enclosed cleaning recommendation.
Maintenance
The radiator is maintenance-free.
Complaints
We are always ready to assist in solving any problems. However,
you can only assert claims arising from legal right against your
contractual partner from whom you bought the product.
Disposal
Recycle used and discarded radiators with accessories or
dispose of them properly. Observe the local regulations.
Optional accessories
Towel rail (42516000) and hooks (42515000) (only permis-
sible at max. supply temperatures of 60 °C)
Folding mirror (42513000)
Paint spot repair stick (95499000)
4
Mounting instructions
EN
Target group
The radiator may only be mounted by a specialist fitter.
Safety instructions
Read the entire user and mounting instructions thoroughly
before carrying out mounting.
After carrying out mounting, hand the instructions over
to the customer.
Danger of crushing!
Always transport and mount the radiator with two
persons.
Wear protective clothing, protective gloves and
safety shoes.
Danger of injury at sharp edges!
Wear protective gloves.
Danger to life!
Check the position of the supply lines (electricity,
gas,water).
Do not drill into the lines.
Danger of injury and property damage if the
radiator falls over!
The supplied screws and screw anchors are only suit-
able for concrete.
In case of other wall structures observe the specifi-
cations of the screw anchor manufacturer.
Conditions of use
The radiator can be used in single- or double-pipe systems.
Use radiators only in closed heating systems.
Observe the water quality (max. water hardness, pH value)
in accordance with VDI 2035 "Avoiding damage in hot-wa-
ter heating systems".
Store and transport radiators only in the packaging. Observe
the instructions on the packaging.
Replace leaking bleed valves and do not close them with a cap.
Repairs
Spare parts (→ Fig. C)
Disposal
Recycle packaging or dispose of it properly. Observe the
local regulations.
Technical features
Operating pressure max. 10 bar (1000 kPa)
Testing pressure
13 bar (1300 kPa)
Supply
Possible on right or left
Supply temperature max. 90 °C
Dimensions
Divider element: 1850 x 553 x 50 x mm
(H x W x D)
Connections
Heating field: 3/8" internal thread

Publicidad

Tabla de contenido
loading

Tabla de contenido