Connection of the hob
The ceramic hob can be connected in different ways:
Monophase 230V~1P+N
Biphase
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the
terminal
Monophase 230V~1P+N
st
Put the 1
bridge between terminal 1 and 2, the 2
Attach the earth to the terminal "earth", the neutral N to terminal 3 or 4, the Phase L to one of
the terminals 1 or 2.
Biphase
400V~2P+N
Put a bridge between terminal 3 and 4.
Attach the earth to the terminal "earth", the neutral N to terminal 3 or 4, the Phase L1 to the
terminals 1 and the Phase L2 to the terminal 2.
Caution ! ensure that you :
- correctly attach the wires and the bridges.
- tighten the screws properly.
Before making the connection, we strongly advise you to locate the phase(s), neutral and
earth on the mains. If you have any doubts, call your electrician.
Note: the bridges between terminals 3-4 and between terminals 1-2 were installed
during the factory check.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.
400V~2P+N
25
nd
between 3 and 4.