WALL SET INSTALLATION (Continued)
13. Secure Side Panel
Top flange
Shim
1-1/4" screws
(panhead or roundhead)
Install side panel, pushing hooks into back panel slots,
pressing firmly into corner and against studs. Push down
until panel tops are even.
Gaps between fl anges and studs must be
IMPORTANT!
less than 1/8". Insert shims to fi ll gaps.
Secure top and side flanges to studs with 1-1/4" screws.
 CAUTION:
Use panhead or roundhead screws. Do not
overtighten screws, this can cause panel to crack.
Repeat steps 12 and 13 to secure other side panel.
15. Apply Sealant
Finished wall
to all seams.
 APPLY SEALANT
IMPORTANT!
Follow manufacturer's instructions for
sealant dry time before use.
Install plumbing fixtures and fittings per manufacturer's
instructions. Check for leaks at all connections before use.
 CAUTION:
If installing fi nished wall material, do not
screw into fl anges or product damage will occur.
14. Brace Side Panels
Less than
1/8" gap
Side
flange
Install temporary braces to hold side panels tight against
studs while adhesive dries.
Protect surface of wall set where it will contact braces.
 CAUTION:
prevent wall panel defl ection.
IMPORTANT!
adhesive dry time before removing brace.
7
Braces should be placed on wall studs to
Follow manufacturer's instructions for
P/N 27748 8/10