Jandy
Section 5. SVLV2 with
Non-Jandy Filter Installation.
a. Versa Coupler p/n 8044
Versa Plumb
connectors can be used to on filters with port
®
distances from 7" to 9" centers. The valve port faces have
four alignment marks. By using the alignment marks on the
versa coupler the following port distances can be achieved:
Alignment Mark
1. Measure the distance between the inlet and
outlet ports on the filter body.
2. Using the Versa Plumb connectors set the
alignment marks to the required position based
on the measurements provided above.
3. Align each versa-coupler to the filter and the
slide valve prior to gluing the assembly. When
the parts are in alignment, mark each piece to
ensure correct reassembly.
b. Installation
WARNING
Ensure that all electrical power to the system is turned
off before approaching, inspecting or troubleshooting
any leaking valves that may have caused other
electrical devices in the surrounding area to get wet.
The following section provides instructions for installing
the Jandy slide valve SLVL2 onto a non-Jandy filter.
This requires at least one versa coupler p/n 8044. The
instructions must be followed exactly. Read through the
instructions completely before starting the procedure.
Please save these instructions.
The slide valve is a two position valve. The valve handle
must be fully extended or fully depressed. This valve can
not be throttled.
1. Remove the slide valve from the packaging.
Twist the handle on the slide valve several times
to verify that the piston moves freely. If any of
the components show signs of damage please
call Zodiac at 1-800-822-7933.
Slide Valve & Backwash Valve
®
PN 8044
7 7"
18 cm Centers
P 7 1/2"
19 cm Centers
S 7 13/16" 20 cm Centers
9 9"
23 cm Centers
|
Installation & Operation Manual
Shown with handle in
Filter position for normal
operation
To Waste
From Pump
Figure 8.
SVLV2 with Versa Couplers Installed
2. Turn off all power to the system.
• For new installations steps "3" through "6" may
be skipped. Proceed to step 7.
3. Open the pressure relief valve on top of the
filter. Wait for all air to evacuate the system.
4. If the filter is installed below pool level, close
the suction and return line valves to isolate the
filtration system or ensure that proper isolation
check valves are in place.
5. Drain the water from the filter. Please follow the
filter manufacturers draining instructions and
ensure that wastewater is disposed of properly.
6. Remove the existing valve from the filter.
7. Follow filter manufacturers instructions for filter
placement on the equipment pad.
8. Slide one (1) versa-coupler into PORT C and
one (1) into PORT D on the slide valve. See
Figure 8.
9. Hold the slide valve up to the filter and twist the
versa-couplers until they slide into the filter inlet
and outlet ports.
10. Remove the valve from the filter. Clean the
versa-couplers and glue them onto the valve
using the alignment marks as a reference.
11. Clean the versa-coupler and glue onto the filter,
or install 2" union tailpieces and union nuts
• The slide valve has molded labels on each port.
• DO NOT USE liquid thread sealant on any
threaded plastic connection.
• If glued, hold the coupler in place for a
minimum of one (1) minute.
12. Plumb the discharge of the pump into the slide
valve inlet labeled PORT B.
ENGLISH
Filter Body
A
C
Filter Inlet
B
D
Filter Outlet
E
Pool Return
Page 9