ADJUSTING THE WELL "FULLY LOWERED" MICROSWITCH
Important
This adjustment must be made with the well
completely lowered.
To carry out this operation, proceed as follows.
1 - Undo the screws (C) and remove the control
panel (D).
2 - Undo the screws (E) to remove the lid (F).
3 - Undo the screw (G).
4 - Position the bracket (H) so that it is touch-
ing the microswitch (L).
5 - Tighten the screw (G).
6 - Fit the lid (F) and secure it with the screw (E).
7 - Replace the control panel (D) on completion of
the operation.
8 - Raise and lower the well to check that the set-
ting is correct (the well must rest firmly on the
IT
fixed part of the appliance).
9 - Switch on the appliance (see page 11) and
check that it operates correctly (the tempera-
GB
ture light must be on).
DE
ADJUSTING THE WELL "FULLY RAISED" MICROSWITCH
FR
Important
ES
This adjustment must be made with the well
completely raised.
To carry out this operation, proceed as follows.
1 - Undo the screws (C) and remove the control
panel (D).