Lengthy Downtimes Of Appliance; Servicing; Recommendations For Servicing - Angelo Po 191BR2EA Manual De Uso E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

If the appliance is to be out of use for a lengthy pe-
riod, proceed as follows.
1 - Cut off the mains electricity supply using the ap-
pliance's master switch.
2 - Clean the appliance and the surrounding areas
thoroughly.
USEFUL ADVICE FOR USE
Important
Use the appliance only for slow cooking
(braising, stewing, sauces, etc.); all other
uses are improper.
To ensure correct use of the appliance, the follow-
ing rules should be adopted.
– Use only the accessories recommended by the
constructor.
– Check that the water level never exceeds the
marked level (A).
– Never use the appliance for frying.

RECOMMENDATIONS FOR SERVICING

Keep the appliance at peak efficiency by carrying
out the scheduled servicing procedures recom-
mended by the constructor. Proper servicing will al-
low the best performance, a longer working life and
constant maintenance of safety requirements.
Caution - warning
Before carrying out any servicing procedure,
activate all the safety devices provided and
decide whether staff at work and those in the
vicinity should be informed. In particular, turn
off the water supply tap, cut off the electricity
supply using the master switch and prevent
access to all devices that might cause unex-
pected health and safety hazards if turned on.

LENGTHY DOWNTIMES OF APPLIANCE

SERVICING

3 - Spread a film of edible oil over the stainless
steel surfaces.
4 - Carry out all the servicing procedures.
5 - Cover the appliance and leave a few gaps to al-
low air to circulate.
At the end of each session of use and whenever
necessary, clean:
– The outer casing
– The well (see page 14)
– The accessories (see page 14)
– The appliance and the surrounding environment
(see page 14)
Every 100 working hours have skilled, authorised
personnel carry out the following operations.
– check that the electrical system is in good work-
ing order
– Check that the well limit stop microswitch is in
good working order
– Check that the safety thermostat is working cor-
rectly
- 13 -
A
IDM-39616001100.tif
5
IT
GB
DE
FR
ES
English

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

191br3ea291br2ea291br3ea

Tabla de contenido