Maintenance - Side Inlet Valve
TO GET THE BEST RESULTS FROM YOUR FLUIDMASTER VALVE,
PLEASE READ THESE INSTRUCTIONS CAREFULLY.
IMPORTANT: ALWAYS CLEAR ANY DEBRIS FROM WATER LINE TO COMPLETE
INSTALLATION
Shut off water supply to toilet cistern or tank, unsnap float adjustment rod from
arm, then remove cap assembly by rotating 1/8 turn anti-clockwise and pulling
out. Hold hand over opening, turn water supply on and off to clear out debris
that may be in supply line. Turn off water supply and replace cap assembly by
engaging lugs and rotating 1/8 turn clockwise to stop. Make certain cap assembly
and valve body are in locked position or valve may fail to turn on. Then snap float
adjustment rod back on to the arm. Turn on water supply.
LOW PRESSURE APPLICATION:
If it takes longer than 4 minutes to refill your cistern, you can increase the flow of
water by removing the flow restrictor.
IMPORTANT: Always clear any debris from water line before installation.
1. Turn off water
supply and loosen
coupling nut by
rotating 1/8 turn
until you hear a
click.
16
2. Pull valve away
from shank.
3. Remove flow
restrictor located
inside the shank.
4. Position valve on
the shank, line up
lugs and tighten
coupling nut by
rotating 1/8 turn
until you hear a
click. Turn on water
supply.