after the first start up of the wine cooler is Red
wine with default temp (16°C) for both zones.
- Program → 2 buttons are available to control
the programs of the two zone. Pressing
program the customer can change the program
of the product in a circular manner between
"Red Wine", "White wine",
"Champagne". The program button will sound
(buzzer sound 0,5s) and the led will change
correspondingly and will show the selected
program; display will show the last setting of
temperature for that program (default
temperature if the program has been selected
for the first time, or the last set temperature).
Program will be applied after 5 seconds the
button is no more pressed. That means that
the control system will start to work after 5
seconds and temperature is set according to
table.
-
^
→ with the 2 temp button for
each zone the customer can change the
temperature (Celsius) of the wine cooler of the
selected program. Temperature will be applied
after 5 seconds if the button is no more
^
pressed. If the
is pressed within 5 sec
after pressed Program button the counter will
start again from zero sec.
- Lights: → pressing it the customer can switch
either on or off both lights together.
The table for temperature range and preset
temperatures for each programme is shown
here below:
PROGRAMME
PRESET
TEMPERATURES
(Celsius)
RED WINE
16°C
WHITE WINE
12°C
CHAMPAGNE
8°C
MIX
14°C
WI-FI MANAGEMENT – ENROLLING
PROCEDURE
The device is equipped with Wi-Fi technology,
which allows you to control it remotely via
App. Make sure you have downloaded the
latest version of the Hoover wizard APP (and
registered your router password to the APP).
TEMPERATURE
RANGE
7-18°C
7-18°C
7-18°C
7-18°C
Pressing the wifi button the led switch on and
will start to blink with duty cycle of 1s on and
1s off. After 5 seconds the easy enrollment
procedure will start and buzzer will sounds for
3 seconds. During this phase the wifi will
continue to blink with same duty cycle. All
other LED are switched off. During the easy
enrollment, the display will show the written
"EE" in the upper digit (the other digit are
switch off). To switch from easy enrollment to
standard enrollment user has to press within 5
minutes the wifi button. After the display
shows the "SE" and the 5 minutes timer is
reset. If the enrollment finishes positively, the
wifi led switches on permanently and the
display shows the temperature and program
previously set (so in this moment 3 LED will be
switched on, the wifi and programs selected
for each zone before start the enrolment). If
no program has been selected, the display will
show the default program (Red Wine with the
default temperature of 16°C). After the
enrollment, the product will be in remote
control mode. Whole process of enrollment
has a timeout of 5 min otherwise has to be
repeated. If the enrollment counter reached
the timeout of 5 min without success the
enrollment of the wine cooler will go back to
the program set before the enrollment
procedure and the wifi module will be
switched off. Enrollment can be aborted by
pressing the ON/OFF button during 5 min from
when it started. Same procedure must be
applied for resetting the enrollment to start a
new one.
ON/OFF button in wifi mode → ON/OFF
switches off the product. All the enrollment
data are saved on the electronic board so
there is no need for a new enrollment at next
power on of the product. Product will go to
read only mode if enrollment was successful
before power off.
Remote control → Product is in read only
mode. Pressing the wifi button, the display will
show "On" for 5 second on the upper part
(during these five sec the
be disabled.) and if no other buttons will be
pressed the wine cooler will change status to
remote control. From now on the APP will fully
control the device. Wifi Led will be fixed. If
there isn't interaction with APP, the product
will be in default program (Red Wine with the
default temperature of 16°C).
^
buttons have to
30