INSTALLATION/OPERATION
Figure 4 - Secure Power Cords
11. Check the pump operation by filling sump with water and
observing pump operation through one complete cycle. For switch
settings see the Electrical and Switch Specifications chart in this
manual.
Risk of flooding. Can cause personal injury and/or
property damage. Failure to make this operational check may lead
to improper operation, premature failure, and flooding.
Figure 5 - Check Pump
MY999-R (06-20-20)

OPERATION

1. Shaft seal depends on water for lubrication. Do not operate pump
unless it is submerged in water as seal may be damaged if allowed
to run dry.
2. Motor is equipped with automatic reset thermal protector. If
temperature in motor should rise excessively, switch will cut off
all power before damage can be done to motor. When motor has
cooled sufficiently, switch will reset automatically and restart
motor. If protector trips repeatedly, pump should be removed and
checked as to cause of difficulty. Low voltage, long extension
cords, clogged impeller, very low head or lift, or a plugged or
6615 0415
frozen discharge pipe, etc., could cause cycling.
3. Pump will not remove all water. If operating a pump manually, and
suddenly no water comes out of the discharge hose, shut off the
unit immediately. The water level is probably very low and the unit
has broken prime.
4829 0205
Risk of electric shock. Can shock, burn or kill. Do not
handle a pump or pump motor with wet hands or when standing
on wet or damp surface, or in water.
Risk of electric shock. Can shock, burn or kill. Before
attempting to check why unit has stopped operating, disconnect
power from unit.