Cable calibration:
This tool must be used every time the cables are replaced. The
device can be equipped with cable of up to 2 x 8 m of cross-section
16 mm².
Calibration was successful.
OK:
A problem occurs during calibration. In this case, the calibra-
FAULT:
tion has been reset to the factory settings. Check the cable condition,
briefly connect the clamps and repeat the process.
ADVANCED MENU (Code 1-9-6-4):
This menu is only suitable for experienced users.
Access to the menu, enter the above code (
number and
to confirm the code).
Start/Stop
Reset Memory (Code 1-9-6-4):
This menu can be reset to the charger's factory settings using the
above code. Your personal settings are deleted.
Reset Memory
RESET MEMORY
Code:
RESET MEMORY
Code NOK
Error Code
Display 1s
RESET MEMORY
RESET MEMORY
23
to change the
Select
0
1
...
0000
9
Änderung
der Zahl
Code OK
(1964)
Code OK
Yes
Reset all ?
No
Advanced Menu
This memory enables the configuration of the expanded settings. To
switch between the settings, press on the
Activate Batteriewechsel-Modus [Battery Change mode] >
SELECT
Activate Power Supply > Activate Expert Curve (> Settings
Configuration Expert Curve)
Activation of Battery Change mode:
To activate Battery Change mode, select the Advanced Menu.
f
Battery change: ON.
f
This mode will therefore be available on the mode list.
3
Activation of «Power Supply» mode:
To activate Power Supply mode, select «ADVANCED MENU»:
f
Power supply: «ON».
f
As a result, this mode is available in the list of modes.
3
Activation of the «EXPERT» curve:
To activate Power Supply mode, select «ADVANCED MENU»:
f
Expert Curve: «ON».
f
As a result, this curve is available in charging mode in the list
3
of charging curves.
button:
Select
23