Descargar Imprimir esta página

Ravaglioli RAV635 MOT4 Manual Del Usuario página 36

Elevador electrohidráulico

Publicidad

INITIAL INSTALLATION INSPECTIONS - LIFT TYPE RAV ...
SERIAL NUMBER...
o Check distance of platforms from any walls (recommended value 1500 mm)  700 mm
o Check internal platform distance
o Check elevation height from floor to platform surface H  1805 mm (recessed lift)
o Check elevation height from floor to platform surface H  1850 mm (floor lift) (RAV635 MOT4)
o Check elevation height from floor to platform surface H  1880 mm (floor lift) (RAV650 MOT4)
o Base levelling, if necessary by placing shims under the base setscrews
o Base levelling by placing shims under the post setscrews (inspection performed with platforms on floor)
o Tighten the anchors securing the bases to the floor
o Tighten the hydraulic pipes between the control unit and bases
o Check oil level in control unit
o Check mains and cable connections
o Start safety devices
o Pneumatic system connection
o Bleed air from hydraulic system
o Check power controls (main switch, up button, down button)
o Check operation of platform realignment valve and platform alignment
o Check engagement of safety pawls on cylinder
o Check pressure switch operation
o Check buzzer operation
o Check up/down times with full load
o Checking cross-beam positioning and fastening on platform level with play detectors
o Checking play detector spotlight operation
o Checking movement of the play detector plates in contemplated directions
o Checking play detector plate reset
DATE
INSTALLER SIGNATURE
36
800 mm (RAV635 MOT4-IMOT4__RAV650 MOT4-IMOT4__RAV650 MOT7-IMOT7)
900 mm (RAV635.2 IMOT4)
0586-M003-1
(RAV650 MOT7)
USER SIGNATURE

Publicidad

loading