23 Troubleshooting Guide
Always remove the connecting cord before carrying out any inspection, cleaning or maintenance.
Condition
LEDs on
Battery
Hedge trimmer cuts
1 LED glows
out during operation.
red.
3 LEDs glow
red.
Runtime is too short.
0458-722-8621-A
Cause
Remedy
Battery too hot / too
► Remove the connecting cord, @ 14.2.
cold.
► Allow the hedge trimmer and battery to cool down gradually
Hedge trimmer too
at ambient temperatures of about 50 °F to 68 °F (10 °C to
hot.
20 °C).
Battery not fully
► Charge the battery as described in its instruction manual.
charged.
Useful life of battery
► Have the battery checked by an authorized STIHL servicing
has been reached or
dealer.
exceeded.