OPTIONAL WIRING
This fixture is provided with a sensor rated for 360 Watts. Since the fixture is only rated 100 Watts,
260 Watts of additional load may be controlled by this sensor.
When determining what a fixture is rated for, do not simply look at the rating on the lamp in the fixture.
Look at the marking which specifies the maximum lamp wattage for which the fixture is suitable.
Once you have selected the fixtures to be connected and determined their maximum ratings, add
these ratings up. For instance, if you have 3 fixtures rated 100 Watts, 150 Watts, and 75 Watts
respectively, you have a total load of 325 Watts.
Wiring Diagram 1 – When wiring to control a standard light fixture: Strip the motion sensor's
red wire and connect to the standard light's black wire. Connect all white wires together. Total
fixture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 2 – When wiring to control another motion sensing light fixture (Master /
Slave): Strip the red wire in both light fixtures. Connect the red wire of the controlling (master)
fixture to the red and black wires of the controlled (slave) fixture. Connect all white wires together.
Total fixture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 3 – When wiring so either motion light turns on both motion lights (Mas-
ter / Master): Strip the red wire in both light fixtures. Connect the red wire of one fixture to the
red wire of the second fixture. Note: In most installations, an additional wire (same gauge as
existing house wire) will have to be installed in the house to connect the two fixtures as master
/ master. Connect all white wires together and all black wires together. Total fixture ratings must
not exceed 360 Watts (3.0 A).
Master
Slave
(Standard)
White
White
Red
Light
Light
Light
Light
Fixture
Fixture
Fixture
Fixture
Red
Black
Black
Green or
Green or
Bare
Bare
Wiring Diagram 1
Wiring Diagram 2
Master
Master
White
Red
Light
Light
Fixture
Fixture
Black
Green or
Bare
Wiring Diagram 3
4