EN
Smoke detector
Product specifications:
Battery:
Alarm output:
Operation temperature:
Operation humidity:
condensing
Quiescent current:
Alarming current:
Dimensions:
Weight:
LED indicator:
Hush status:
Standby status:
Low battery status:
replacement
Installation
• Choose an appropriate position to install the alarm on a ceiling
away from obstructions, doors, windows, ventilator and radiator
and at least 50cm from fluorescent lights and low energy bulb.
• Use the screws and plugs provided to secure the installation
panel securely to the ceiling.
• Align the 2 locating slots in the smoke detector with the 2 tags
on the installation panel and rotate it clockwise until it locks into
position.
Testing and usage
• Turn the smoke detector anti-clockwise to remove it from the
installation panel.
• Install the 9V battery supplied and ensure it is clipped behind
the red security arm at the side of the panel.
• Align the 2 locating slots in the smoke detector with the 2 tags
on the installation panel and rotate it clockwise until it locks into
position.
• Press and hold the TEST/HUSH button. The LED flashes
1 x 9V 6F22
≥85dB/3m
-10°C - 40°C
≤95% Relative humidity with no water
≤12µA
≤20mA
36mm x 102mmØ
140g
Red LED
LED flashes every 10s
LED flashes every 43s
Beep around every 43s and need battery