Dip Switch
Function
Dip 1 = OFF
Infrared sensor sensitive area up to 6 m
Dip 2 = OFF
Dip 1 = ON
Infrared sensor sensitive area up to 8 m
Dip 2 = OFF
Dip 1 = OFF
Infrared sensor sensitive area up to 10 m
Dip 2 = ON
Dip 1 = ON
Infrared sensor sensitive area up to 12 m
Dip 2 = ON
Dip 3 = OFF
N° infrared pulses for alarm = 1
Dip 3 = ON
N° infrared pulses for alarm = 2
Dip 4 = OFF
Signalling leds active
Dip 4 = ON
Signalling leds off
Dip 5 = OFF
Rear tamper protection active
Dip 5 = ON
Rear tamper protection deactivated
Dip 6 = OFF
Temperature compensation deactivated
Dip 6 = ON
Temperature compensation activated