Garantiemeldung:
(GB) Devices with a BP7VA drive - C 200 problem
General:
Complaint:
Cause:
Action:
Warranty report:
Kundenbeanstandung:
Klassifizierung (Fehlerort):
Bauteil:
Position-Nr.:
ausgeführte Arbeit:
All OEM radio and navigation devices stated in the „BP7-Overview-
VA_v09R3.pdf" list.
Drive reading problems at low temperatures.
1. In the case of CR e.g.:
2. In the case of DI e.g.:
At low temperatures (below approx. -15°C) the capacitor does not comply with
its specified values.
The CD drive number must be checked for the stated devices. If the drive's
MFD is before the 1.10.2005 (Industrial Date 8111), it is possible that the
device is fitted with the „faulty" capacitor.
Irrespective of whether the fault has emerged in the device or not, the
specified capacitor C200 (electrolyte) must be replaced with a replacement
from TDK (ceramic). (Replacement part no. 8 619 003 168).
For details on this, please refer to the enclosure „Work instruction -
exchanging the mode select switch in BP7-mechanisms"; this is the currently
applicable version. The current version must be used in each case. This can
be found at::
file://hi230059\daten$\Daten\P-Handbuecher\QS9000\
Int Managementhandbook\Anhang Englisch\
Appendix04\AAW BP7 Mode switch.pdf
This action is applicable for the CM-AS's own repair shops in Hildesheim,
Portugal, Hungary and Malaysia as well as in the case of individual repair for
Belgium and Turkey.
In the case of devices that are older than 24 months according to their device
MFD, the entire drive must be replaced.
Exceptions: In the case of Opel devices, exchange after 12 months.
The replacement part number of the drive must be obtained from the relevant
workshop systems (Ares/Remas).
Customer complaint:
Classification (failure location):
Component:
Item no.:
Work performed:
60A
5
C
0200
W
CD mode does not function
Navi does not boot
60A
5
C
0200
W