If the Green LED DL2 flashes six times, it means that the radio code
memory is FULL (maximum codes to be stored 60).
4 - Turn DIP1 to OFF position.
5 - Turn DIP2 to OFF position.
6 - LED L9 and LED L10 turn OFF.
F
UNCTIONING OF CONTROL ACCESSORIES
STEP BY STEP or AUTOMATIC commands
(K BUTT button, PED BUTT button, RADIO REMOTE button)
DIP 6 - ON The K BUTT, the PED BUTT button, the RADIO REMOTE
buttons perform the cyclic command open-stop-close-
open-stop-etc.
DIP 6 - OFF The K BUTT, the PED BUTT button, the RADIO REMOTE
buttons perform:
- the open command, if pressed with the gate completely
closed
- the close command, if pressed with the gate completely
opened
- no effect, if pressed during the gate opening
- the gate re-open, if pressed while the gate is closing
The K BUTT opens the gate completely, whereas the PED BUTT opens
the gate partially as described in Point F.
CLOCK FUNCTION (available ONLY with DIP 6 OFF)
The Clock Function permits to keep the gate opened even if, for
example, the Automatic Closing is enabled (DIP3 ON) or somebody
commands the gate closing. It is useful during rush hours, when traffic
is heavy and the flow is slow (e.g. entrance/exit of employees,
emergencies in residential areas or car parks and, temporarily, for
removal vans) and it's necessary to keep the gate opened.
It can be done by connecting a switch and/or a daily/weekly clock either
in parallel to the K BUTT button or instead of the K BUTT button. When
the control board receives this command, the gate will open and by
keeping this contact closed for all the time of the gate opening, the
Clock Function is automatically activated. In fact, once reached the
open position, the gate will remain opened and all of the control board
functions are blocked. Only when K BUTT contact is released, the
control board functions are re-activated and the Automatic Closing
restarts (if enabled) doing the countdown to the gate closing.
PEDESTRIAN command (PED BUTT - COM)
This command is useful to open the gate partially, just enough, for
example, to permit a pedestrian crossing. In fact, the Pedestrian
command (see Point F) is carried out only by opening the motor M1 just
enough for a pedestrian to pass, as described into the Point F
procedure.
From the Pedestrian opening position the Automatic Closing can be
enabled or disabled with DIP3.
From the Pedestrian opening position, the gate can be completely
opened by the OPEN or by the K BUTT button or by the RADIO button.
AUTOMATIC CLOSING (from the COMPLETE open position)
The Automatic Closing from the complete open position can be enabled
turning ON the DIP3.
The maximum gap of time that can be programmed is 5 minutes (see
Point D and E).
AUTOMATIC CLOSING (from the PEDESTRIAN open position)
The Automatic Closing from the pedestrian open position can be
enabled turning ON the DIP3. The maximum gap of time that can be
programmed is 5 minutes (see Point F).
ELECTRIC LOCK (LOCK A+) command
The DIP 8 in the ON position enables the Electric Lock (MAX 15W 12V)
command. The Electric Lock (LOCK A+) will be automatically turned ON
each time the gate opens.
If the DIP8 is OFF, the Electric Lock command is DISABLED.
MANUAL RELEASE FACILITY
The DIP 9 in the ON position enables the Manual Release Facility.
Once the gate has completely closed, a short reversal manoeuvre (0.2
seconds) will be done to ease manual release.
ELECTRIC LOCK unlocking FACILITY
The DIP 9 in the ON position enables the Electric Lock unlocking
Facility. From close position, just before opening, the gate will perform
a short closing manoeuvre (0.5 seconds) to ease unlocking from
electric lock.
ELECTRIC LOCK coupling FACILITY
The DIP 10 in the ON position enables the Electric Lock coupling
Facility. Once the gate has closed, a short hammering close pulse (0.5
seconds) will be done at full power to guarantee the electric lock or
mechanical bolt coupling.
F
UNCTIONING OF SAFETY ACCESSORIES
PHOTOCELL (PHOT - COM)
In case the switch DIP4 is in the OFF position, the photocells are active
both in gate opening and in gate closing. In this configuration, if an
obstacle cuts the photocell beam:
- while the gate is closing, the gate will open
- while the gate is opening, the gate will stop and will restart opening
when the obstacle is removed
- while the gate is still, it will not move neither in opening nor in closing.
In case of the switch DIP4 is in the ON position, the photocells are
active only in gate closing.
In this configuration, if an obstacle cuts the photocell beam:
- while the gate is closing, the gate will open
- while the gate is opening, the gate will continue open
- while the gate is still, it will open if a open command is request, it will
remain still if a close command is request.
The photocell input (PHOT - COM) is a NORMALLY CLOSED contact.
In case there are more couple of photocells, the contacts from all the
photocell receivers must be connected in series.
In case the photocells are not installed, this contact must be short
circuited with a wire jump (from PHOT to COM) to permit the gate to
operate.
SAFETY STRIP (EDGE - COM)
If an obstacle presses the safety strip:
- while the gate is still, it will not move neither in opening nor in closing
- while the gate is closing, the gate will open
- while the gate is opening, the gate will close.
In case the safety strip is held pressed a further quick reversion, after 2
seconds, is performed. The gate interrupts any movement and this
alarm state is indicated by 1 minute Blinker flashing. The normal gate
operations can be restored by pressing any push button or radio
commands.
The safety strip input (EDGE - COM) is a NORMALLY CLOSED
contact.
In case there are more than one safety strip, all their contacts must be
connected in series.
In case the safety strip is not installed, this contact must be short
circuited with a wire jump (from EDGE to COM) to permit the gate
to operate and the Safety Strip test must be disabled (DIP 13 OFF).
TESTING THE SAFETY STRIP equipment
The switch DIP13 ON enables to test the safety strip equipment. The
test is performed every time the gate completes a full opening. The test
is available only if the safety strip device is equipped with a
dedicated power supply input.
In fact, the safety strip equipment power supply input can be connected
G G
B B