Important: Read complete instructions before beginning installation.
Each whirlpool bath arrives ready for installation, completely equipped with motor/pump assembly and plumbing and fittings necessary for
whirlpool operation. An optional drain/overflow kit is available for installation on the bath.
Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Do not lift the bath
by the plumbing at any time; handle by the shell only.
Immediately upon receipt, inspect the shell before installing. Should inspection reveal any damage or defect in the finish, do not install the
bath. Damage or defect to the finish claimed after the bath is installed is excluded from the warranty. Eljer's responsibility for shipping damage
ceases upon delivery of the products in good order to the carrier. Refer any claims for damage to the carrier. For definitions of warranty coverage
and limitations, refer to the published warranty information packed with the product.
All bath units are factory tested for proper operation and watertight connections prior to shipping. Note: Prior to installation, the bath must
be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling. Eljer is not respon-
sible for any defect that could have been discovered, repaired, or avoided by following this inspection and testing procedure.
Importante: Lea las instrucciones antes de iniciar la instalación.
Las tinas de hidromasaje se entregan listas para instalarse y completamente equipadas con motor, bomba, accesorios de plomería y mecanismos
necesarios para el hidromasaje. La instalación del equipo de desagüe y rebosadero es opcionál.
Saque la tina de su caja; consérvela hasta haber revisado completamente el producto. No levante la tina sujetándola por los accesorios
de plomería, sino por el casco.
Inspeccione el casco de la tina en cuanto la reciba. En caso de que detecte algún daño o desperfecto en el terminado, no la instale. La
garantía no cubre daños o desperfectos reclamados después de la instalación. La responsabilidad de Eljer por daños de embarque termina al
entregar los productos en buen estado al distribuidor. Presente sus reclamaciones por daños al distribuidor. Para mayor información sobre la
cobertura de la garantía, consulte la garantía publicada en el empaque del producto.
El funcionamiento de las tinas y el buen estado de las conexiones han sido probados en fábrica antes del embarque. Nota: Antes de la
instalación, llene la tina con agua y enciéndala para verificar que no presente fugas provocadas durante el embarque o por mal
manejo. Eljer no se hace responsable por desperfectos que pudieran haberse descubierto, reparado o evitado de haberse seguido este
procedimiento de inspección y verificación.
L
H
SIDE VIEW
VISTA LATERAL
2"
H1
51 mm
SPECIFICATIONS
MODEL
MODELO
CAYMAN
CHARLESTON 36
CHARLESTON 42
FOR ALL UNITS:
MOTOR/PUMP: 115 VAC, 3450 RPM/10 AMP, 60 Hz Single phase.
ELECTRICAL REQUIREMENTS: 115 VAC, 15 AMP, 60 Hz. Requires
dedicated separate circuit.
W
END VIEW
VISTA DE FRENTE
CAYMAN
H2
SIDE VIEW
VISTA LATERAL
CHARLESTON 36 & 42
ESPECIFICACIONES
(Rectangular)
DRAIN/OVERFLOW
DIMENSIONS
MEDIDAS DEL
DIMENSIONS
DESAGÜE/
MEDIDAS
REBOSADERO
72" (1829 mm) L
16-3/8" (416 mm) A
42" (1067 mm) W
10-1/4" (260 mm) B
20" ( 508 mm) H
9"
(229 mm) A
72"
(1829 mm) L
15-5/16" (389 mm) B
36"
( 914 mm) W
22-7/8" ( 581 mm) H1
21"
( 533 mm) H2
23-5/8" ( 600 mm) H3
9"
(229 mm) A
72"
(1829 mm) L
15-5/16" (389 mm) B
42"
(1067 mm) W
22-7/8" ( 581 mm) H1
21"
( 533 mm) H2
23-5/8" ( 600 mm) H3
2"
51 mm
H3
(Rectangular)
TOTAL WEIGHT/
OPERATING
FLOOR LOADING
CUTOUT
GALLONAGE
CARGA TOTAL
CAPACIDAD
CORTE
SOBRE EL PISO
72 U.S. gal
915 lb
70" x 40"
(415 kg)/
(273 litros)
44 lb/sq. ft.
(215 kg/sq. m)
See
850 lb
70 U.S. gal
Page 4
(386 kg)/
(265 litros)
Vea
49 lb/sq. ft.
Pagina 4
(239 kg/sq. m)
See
1030 lb
90 U.S. gal
(467 kg)/
Page 4
(341 litros)
40 lb/sq. ft.
Vea
(195 kg/sq. m)
Pagina 4
PARA TODAS LAS UNIDADES:
Motor/bomba: 115 VCA, 3450 RPM/10 AMP, 60 Hz, Monofásico.
Requisitos eléctricos: 115 VCA, 15 AMP, 60 Hz. Requiere un
circuito dedicado independiente.
2
A
B
DRAIN/OVERFLOW
DESAGÜE/REBOSADERO
W
END VIEW
VISTADE FRENTE
SKIRT &
PRODUCT
MOUNTING
WEIGHT
FALDÓN Y
PESO
MONTAJE
140 lb
Optional
(64 kg)
Opcional
115 lb
None
(52 kg)
130 lb
None
(59 kg)