1.5 Technical details and technical plate
Technical details are reported on following table:
Plan
burner
Max
MOD.
13.5kW
Min
5kW
G0221
1
G0222
1
G0260
1
G0261
1
G0263
1
G0264
1
Technical plate:
The technical plate is attached inside cock's dashboard or open stand. You find a copy here enclosed.
1.6 Tests and functioning
Check the technical data plate that the appliance has been tested for the type of gas with
•
which it is to be operated, on the contrary to carry on with the transformation as
paragraph 1.7
Always check the pressure of the gas supply. For this purpose, use the pressure test outlet
•
provided on the appliance (see paragraph 1.4), following this procedure:
a)
close the central gas cock for safety reason;
b)
take away the screw and lock washer from pressure outlet;
c)
connect the graduated manometer (1 mbar = 10 mm c.a.) and turn on the appliance
to maximal power;
d)
check that the pressure value corresponds to reported value of schedule in the
paragraph 1.5;
Burner
Burner
Oven
"G"
Max
Max
Max
8.4kW
8.4 Kw
6kW
Min
Min
2.5kW
2.5kW
1.8kW
1
1
1
1
2
1
2
Burner
"M"
"P"
Total
Max
Power
3.5kW
kW
Min
Min
1.1kW
13.50
21.9
1
25.4
1
33.8
1
1
39.8
1
1
48.2
20/72
mod. G02
Consumption
Consumption
G30 mbar
G20 mbar20
28-30
G31 mbar37
m³/h
Kg/h
1.43
1.06
2.32
1.72
2.68
3.57
2.66
4.21
3.14
5.1
3.8
2